5VP Series HIGH POWER PROGRAMMABLE DC LOADS
The 5VP Series consists of high power load cabinet systems with support for 60V, 600V or 1000V input ranges.
All loads share a common and intuitive user interface. The 5VP Series are highly efficient integrated DC load systems that operate from a single user control panel or remote control interface.
There are 24 different 5VP Series models ranging from 5kW to 60kW. For higher power requirements, 5VP models can be paralleled easily.
For questions regarding the 5VP Series DC Loads, please contact us.
The Adaptive Power 5VP Series loads are intended for very high power DC test and product development applications in a wide range of industries. The 5VP Series models support voltages to 60V, 600V or 1000V and are well suited for testing large battery systems, high power AC/DC converters and energy storage systems found in Solar and Wind power applications. Their flexible V-I operating curves span range of voltage and current combinations at high power levels. All 5VP Series models have a low range mode for enhanced accuracy and resolution at lower voltage and current levels, further increasing their effectiveness.
The 5VP Series consists of a total of 24 different models providing a wide variation of possible voltage, current and power combinations.
5VP Series Models – 60 Vdc
Model | 5VP05-100 | 5VP10-100 | 5VP15-100 | 5VP20-100 | ||||
---|---|---|---|---|---|---|---|---|
OPERATING RANGES | ||||||||
Power Ranges | 0-0.5 kW | 0-5 kW | 0-1.0 kW | 0-10 kW | 0-1.5 kW | 0-15 kW | 0-2.0 kW | 0-20 kW |
Current Ranges | 0 – 100 A | 0 – 1000 A | 0 – 100 A | 0 – 1000 A | 0 – 100 A | 0 – 1000 A | 0 – 100 A | 0 – 1000 A |
Voltage Range | 0 – 60 V | |||||||
Minimum Voltage | 0.1 V @ 100 A | 0.7 V @ 1000 A | 0.1 V @ 100 A | 0.7 V @ 1000 A | 0.1 V @ 100 A | 0.7 V @ 1000 A | 0.1 V @ 100 A | 0.7 V @ 1000 A |
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP), Constant Current + Constant Voltage (CC+CV) and Constant Power + Constant Voltage (CV) | |||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||||
DYNAMIC OPERATION |
||||||||
T high & T low | 0.150-9.999/…/9999ms | 0.050-9.999 / 99.99 / 999.9 / 9999ms (20 kHz) | ||||||
Slew Rate | 24mA-1.5A/μs | 240mA-15A/μs | 66.4mA-4.15A/μs | 664mA-41.5A/μs | 66.4mA-4.15A/μs | 664mA-41.5A/μs | 66.4mA-4.15A/μs | 664mA-41.5A/μs |
METERING | ||||||||
Voltage Range | 0 – 6 V | 6 – 60 V | 0 – 6 V | 6 – 60 V | 0 – 6 V | 6 – 60 V | 0 – 6 V | 6 – 60 V |
Current Range | 0 – 100 A | 0 – 1000 A | 0 – 100 A | 0 – 1000 A | 0 – 100 A | 0 – 1000 A | 0 – 100 A | 0 – 1000 A |
Power Range | 0 – 500 W | 0 – 5000 W | 0 – 1000 W | 0.600 – 10 kW | 0 – 1500 W | 600 – 15000 W | 0 – 2000 W | 0.6 – 20 kW |
SHORT CIRCUIT CURRENT | 1000 A | |||||||
AC INPUT & PHYSICAL SPECIFICATIONS | ||||||||
AC Input/Cooling | 115/230 Vac ±10%, 50/60Hz / Variable Speed Fan Cooled | |||||||
Dimensions (HxWxD) |
577 x 647 x 766 mm 22.7″ x 25.5″ x 30.2″ |
736 x 647 x 766 mm 29″ x 25.5″ x 30.2″ |
889 x 647 x 766mm 29″ x 25.5″ x 35″ |
|||||
Weight (Net) | 100kg / 220.5 lbs | 130kg / 286.6 lbs | 170kg / 374.8 lbs | 220kg / 485.0 lbs |
Model | 5VP25-100 | 5VP30-100 | 5VP05-16 | 5VP10-32 | |||||
---|---|---|---|---|---|---|---|---|---|
OPERATING RANGES | |||||||||
Power Ranges | 0-2.5 kW | 0-25 kW | 0-3.0 kW | 0-30 kW | 0-0.5 kW | 0-5 kW | 0-1.0 kW | 0-10 kW | |
Current Ranges | 0 – 100 A | 0 – 1000 A | 0 – 100 A | 0 – 1000 A | 0 – 16 A | 0 – 160 A | 0 – 32 A | 0 – 320 A | |
Voltage Range | 0 – 60 V | ||||||||
Minimum Voltage | 0.1 V @ 100 A | 0.7 V @ 1000 A | 0.1 V @ 100 A | 0.7 V @ 1000 A | 20 V @ 160 A | 20 V @ 320 A | |||
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP), Constant Current + Constant Voltage (CC+CV) and Constant Power + Constant Voltage (CV) | ||||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | ||||||||
DYNAMIC OPERATION |
|||||||||
T high & T low | 0.050-9.999 / 99.99 / 999.9 / 9999ms (20 kHz) | ||||||||
Slew Rate | 66.4mA-4.15A/μs | 664mA-41.5A/μs | 66.4mA-4.15A/μs | 664mA-41.5A/μs | 12.8mA-800mA/μs | 128mA-8A/μs | 25.6mA-1.6A/μs | 256mA-16A/μs | |
METERING | |||||||||
Voltage Range | 0 – 6 V | 6 – 60 V | 0 – 6 V | 6 – 60 V | 0 – 6 V | 60 – 600 V | 0 – 60 V | 60 – 600 V | |
Current Range | 0 – 100 A | 100 – 1000 A | 0 – 100 A | 100 – 1000 A | 0 – 16 A | 16 – 160 A | 0 – 32 A | 32 – 320 A | |
Power Range | 0 – 2500 W | 0 – 2500 W | 0 – 3000 W | 0 – 30000 W | 0 – 500 W | 0 – 5000 W | 0 – 1000 W | 0 – 10000 W | |
SHORT CIRCUIT CURRENT | 1000 A | 160 A | 320 A | ||||||
AC INPUT & PHYSICAL SPECIFICATIONS | |||||||||
AC Input/Cooling | 115/230 Vac ±10%, 50/60Hz / Variable Speed Fan Cooled | ||||||||
Dimensions (HxWxD) |
1048 x 647 x 766 mm 22.7″ x 25.5″ x 30.2″ |
1201 x 647 x 766 mm 47.3″ x 25.5″ x 30.2″ |
577 x 647 x 766 mm 29″ x 25.5″ x 30.2″ |
577 x 647 x 766 mm 29″ x 25.5″ x 30.2″ |
|||||
Weight (Net) | 280kg / 617.3 lbs | 340kg / 749.6 lbs | 100kg / 220.5 lbs | 130kg / 286.6 lbs |
5VP Series Models – 600 Vdc
Model | 5VP15-48 | 5VP20-64 | 5VP25-80 | 5VP30-96 | ||||
---|---|---|---|---|---|---|---|---|
OPERATING RANGES | ||||||||
Power Ranges | 0-1.5 kW | 0-15 kW | 0-2.0 kW | 0-20 kW | 0-2.5 kW | 0-25 kW | 0-3.0 kW | 0-30 kW |
Current Ranges | 0 – 48 A | 0 – 480 A | 0 – 64 A | 0 – 640 A | 0 – 80 A | 0 – 800 A | 0 – 96 A | 0 – 960 A |
Voltage Range | 0 – 600 V | |||||||
Minimum Voltage | 20 V @ 480 A | 20 V @ 640 A | 20 V @ 800 A | 20 V @ 960 A | ||||
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP), Constant Current + Constant Voltage (CC+CV) and Constant Power + Constant Voltage (CV) | |||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||||
DYNAMIC OPERATION |
||||||||
T high & T low | 0.050-9.999 / 99.99 / 999.9 / 9999ms (20 kHz) | |||||||
Slew Rate | 38.4mA-2.4A/μs | 384mA-24A/μs | 51.2mA-3.2A/μs | 512mA-32A/μs | 64mA-4A/μs | 640mA-40A/μs | 76.8mA-4.8A/μs | 768mA-48A/μs |
METERING | ||||||||
Voltage Range | 0 – 60 V | 60 – 600 V | 0 – 60 V | 60 – 600 V | 0 – 60 V | 60 – 600 V | 0 – 60 V | 60 – 600 V |
Current Range | 0 – 48 A | 48 – 480 A | 0 – 64 A | 64 – 640 A | 0 – 80 A | 80 – 800 A | 0 – 96 A | 96 – 960 A |
Power Range | 0 – 1500 W | 0 – 15000 W | 0 – 2000 W | 0 – 20000 W | 0 – 2500 W | 0 – 25000 W | 0 – 3000 W | 0 – 30000 W |
SHORT CIRCUIT CURRENT | 480 A | |||||||
AC INPUT & PHYSICAL SPECIFICATIONS | ||||||||
AC Input/Cooling | 115/230 Vac ±10%, 50/60Hz / Variable Speed Fan Cooled | |||||||
Dimensions (HxWxD) |
73 6 x 647 x 766mm 29″ x 25.5″ x 30.2″ |
889 x 647 x 766mm 5″ x 25.5″ x 30.2″ |
1048 x 647 x 766mm 41.3″ x 25.5″ x 30.2″ |
1201 x 647 x 766mm 47.3″ x 25.5″ x 30.2″ |
||||
Weight (Net) | 170kg / 374.8 lbs | 220kg / 485.0 lbs | 280kg / 617.3 lbs | 340kg / 749.6 lbs |
Model | 5VP50-21 | 5VP60-24 | 5VP50-50 | 5VP60-60 | ||||
---|---|---|---|---|---|---|---|---|
OPERATING RANGES | ||||||||
Power Ranges | 0-5.0 kW | 0-50 kW | 0-6.0 kW | 0-60 kW | 0-5.0 kW | 0-50 kW | 0-6.0 kW | 0-60 kW |
Current Ranges | 0 – 21 A | 0 – 210 A | 0 – 24 A | 0 – 240 A | 0 – 52.5 A | 0 – 500 A | 0 – 60 A | 0 – 600 A |
Voltage Range | 0 – 600 V | |||||||
Minimum Voltage | 20 V @ 210 A | 20 V @ 240 A | 20 V @ 500 A | 20 V @ 600 A | ||||
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP), Constant Current + Constant Voltage (CC+CV) and Constant Power + Constant Voltage (CV) | |||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||||
DYNAMIC OPERATION |
||||||||
T high & T low | 0.050-9.999 / 99.99 / 999.9 / 9999ms (20 kHz) | |||||||
Slew Rate | 16.8mA-1.05A/us | 168mA-10.5A/us | 19.2mA-1.2A/us | 192mA-12A/us | 42mA-2.625A/us | 420mA-26.25A/us | 48mA-3A/us | 480mA-30A/us |
METERING | ||||||||
Voltage Range | 0 – 60 V | 60 – 600 V | 0 – 60 V | 60 – 600 V | 0 – 100 V | 100 – 1000 V | 0 – 100 V | 100 – 1000 V |
Current Range | 0 – 21 A | 21 – 210 A | 0 – 24 A | 24 – 240 A | 0 – 52.5 A | 52.5 – 500 A | 0 – 60 A | 60 – 600 A |
Power Range | 0 – 5 kW | 0 – 50 kW | 0 – 6 kW | 0 – 60 kW | 0 – 5 kW | 0 – 50 kW | 0 – 6 kW | 0 – 60 kW |
SHORT CIRCUIT CURRENT | 210 A | 240 A | 500 A | 600 A | ||||
AC INPUT & PHYSICAL SPECIFICATIONS | ||||||||
AC Input/Cooling | 115/230 Vac ±10%, 50/60Hz / Variable Speed Fan Cooled | |||||||
Dimensions (HxWxD) |
1360 x 853 x 766 mm 53.6″ x 33.6″ x 30.2″ |
1513 x 853 x 766 mm 59.6″ x 33.6″ x 30.2″ |
1360 x 853 x 766 mm 53.6″ x 33.6″ x 30.2″ |
1513 x 853 x 766 mm 59.6″ x 33.6″ x 30.2″ |
||||
Weight (Net) | 510kg / 1124.4 lbs | 630kg / 1388.9 lbs | 510kg / 1124.4 lbs | 630kg / 1388.9 lbs |
5VP SERIES MODELS – 1000 VDC
Model | 5VP05-05 | 5VP10-10 | 5VP15-15 | 5VP20-20 | ||||
---|---|---|---|---|---|---|---|---|
OPERATING RANGES | ||||||||
Power Ranges | 0-0.5 kW | 0-5 kW | 0-1.0 kW | 0-10 kW | 0-1.5 kW | 0-15 kW | 0-2.0 kW | 0-20 kW |
Current Ranges | 0 – 5 A | 0 – 50 A | 0 – 10 A | 0 – 100 A | 0 – 15 A | 0 – 150 A | 0 – 20 A | 0 – 200 A |
Voltage Range | 0 – 1000 V | |||||||
Minimum Voltage | 20 V @ 50 A | 20 V @ 100 A | 20 V @ 150 A | 20 V @ 200 A | ||||
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP), Constant Current + Constant Voltage (CC+CV) and Constant Power + Constant Voltage (CV) | |||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||||
DYNAMIC OPERATION |
||||||||
T high & T low | 0.050-9.999 / 99.99 / 999.9 / 9999ms (20 kHz) | |||||||
Slew Rate | 0.004A-0.25A/μs | 0.04A-2.5A/μs | 0.008A-0.5A/μs | 0.08A-5A/μs | 0.012A-0.75A/μs | 0.12A-7.5A/μs | 0.016A-1A/μs | 0.16A-10A/μs |
METERING | ||||||||
Voltage Range | 0 – 100 V | 100 – 1000 V | 0 – 100 V | 100 – 1000 V | 0 – 100 V | 100 – 1000 V | 0 – 100 V | 100 – 1000 V |
Current Range | 0 – 5 A | 5 – 50 A | 0 – 10 A | 10 – 100 A | 0 – 15 A | 15 – 150 A | 0 – 20 A | 20 – 200 A |
Power Range | 0 – 0.55 kW | 0 – 5 kW | 0 – 1.0 kW | 0 – 10 kW | 0 – 1.5 kW | 0 – 15 kW | 0 – 2.0 kW | 0 – 20 kW |
SHORT CIRCUIT CURRENT | 50 A | 100 A | 150 A | 200 A | ||||
AC INPUT & PHYSICAL SPECIFICATIONS | ||||||||
AC Input/Cooling | 115/230 Vac ±10%, 50/60Hz / Variable Speed Fan Cooled | |||||||
Dimensions (HxWxD) |
577 x 647 x 766 mm 29″ x 25.5″ x 30.2″ |
736 x 647 x 766 mm 29″ x 25.5″ x 30.2″ |
736 x 647 x 766 mm 29″ x 25.5″ x 30.2″ |
889 x 647 x 766 mm 29″ x 25.5″ x 30.2″ |
||||
Weight (Net) | 100kg / 220.5 lbs | 130kg / 286.6 lbs | 170kg / 374.8 lbs | 220kg / 485.0 lbs |
Model | 5VP25-25 | 5VP30-30 | 5VP35-35 | 5VP40-40 | ||||
---|---|---|---|---|---|---|---|---|
OPERATING RANGES | ||||||||
Power Ranges | 0-2.5 kW | 0-25 kW | 0-3.0 kW | 0-30 kW | 0-3.5 kW | 0-35 kW | 0-4.0 kW | 0-40 kW |
Current Ranges | 0 – 25 A | 0 – 250 A | 0 – 30 A | 0 – 300 A | 0 – 35 A | 0 – 350 A | 0 – 40 A | 0 – 400 A |
Voltage Range | 0 – 1000 V | |||||||
Minimum Voltage | 20 V @ 250 A | 20 V @ 300 A | 20 V @ 350 A | 20 V @ 400 A | ||||
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP), Constant Current + Constant Voltage (CC+CV) and Constant Power + Constant Voltage (CV) | |||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||||
DYNAMIC OPERATION |
||||||||
T high & T low | 0.050-9.999 / 99.99 / 999.9 / 9999ms (20 kHz) | |||||||
Slew Rate | 0.02A-1.25A/μs | 0.2A-12.5A/μs | 0.024A-1.5A/μs | 0.24A-15A/μs | 0.028A-1.75A/μs | 0.28A-17.5A/μs | 0.032A-2A/μs | 0.32A-20A/μs |
METERING | ||||||||
Voltage Range | 0 – 100 V | 100 – 1000 V | 0 – 100 V | 100 – 1000 V | 0 – 100 V | 100 – 1000 V | 0 – 100 V | 100 – 1000 V |
Current Range | 0 – 25 A | 25 – 250 A | 0 – 30 A | 30 – 300 A | 0 – 35 A | 35 – 350 A | 0 – 40 A | 40 – 400 A |
Power Range | 0 – 2500 W | 0 – 25000 W | 0 – 3000 W | 0 – 30000 W | 0 – 3500 W | 0 – 35000 W | 0 – 4000 W | 0 – 40000 W |
SHORT CIRCUIT CURRENT | 250 A | 300 A | 350 A | 400 A | ||||
AC INPUT & PHYSICAL SPECIFICATIONS | ||||||||
AC Input/Cooling | 115/230 Vac ±10%, 50/60Hz / Variable Speed Fan Cooled | |||||||
Dimensions (HxWxD) |
1048 x 647 x 766 mm 41.3″ x 25.5″ x 30.2″ |
1201 x 647 x 766 mm 47.3″ x 25.5″ x 30.2″ |
1360 x 647 x 766 mm 53.6″ x 25.5″ x 30.2″ |
1513 x 647 x 766 mm 59.6″ x 25.5″ x 30.2″ |
||||
Weight (Net) | 280kg / 617.3 lbs | 340kg / 749.6 lbs | 390kg / 859.8 lbs | 430kg / 948.0 lbs |
Mainframes
Mainframe | 44M01 | 44M02 | 44M04 | |
---|---|---|---|---|
No. of Slots | 1 | 2 | 4 | |
Supports |
41L0630, 41L0660, 41L2512, 41:5012, 41L0616 42L0860, 42L0824, 42L0803 41D3024, 41D5012, 41D5024, 42D5006 |
|||
Max Power | 300W | 600W | 1200W | |
AC Input | 100-115Vac ±10% or 200-230Vac ±10% | |||
Frequency | 50 / 60 Hz ±3Hz | |||
Power (max.) | 40W | 60W | 150W | |
Dimensions (HxWxD) |
177x160x452mm 7.0×6.3×17.8″ |
177x269x452mm 7.0×10.6×17.8″ |
177x440x445mm 7.0×17.3×17.5″ |
|
Weight | 5.5 kg / 12.2 lbs | 7.5 kg / 16.5 lbs | 9.3 kg / 20.5 lbs |
Low Voltage Range, 0 – 6 Vdc
Voltages up to 1000Vdc
Current Ranges up to 1000 Adc
High-Speed 5 Digit Precision Metering Capability
Parallel Operation for High Power Applications
Compact Design
Movable Cabinet on lockable Casters
Operating Modes: CC, CP, CR, CV, CC+CV, CP+CV
MPPT Mode for Solar Panel Development and Test
Built-in Short Circuit Test
Over Current Protection Test Mode
Over Power Protection Test Mode
Static and Dynamic CC Modes
Available Interface Options are USB, RS232, GPIB and LAN
CE Mark
All APS 5VP Series Loads are equipped with a powerful microcontroller and user friendly controls to provide capabilities that cover a wide range of load applications. Precision metering of Voltage, Current, Power and Resistance is standard.
Power Supply Testing
Elaborate testing of linear and switch mode AC/DC power supplies at high speeds is made possible by flexible ranging and wide V-I operating curves found in all 5VP Series APS loads. This supports high throughput production test and burn-in of small and large AC/DC power supplies.
Power Supply Design
With built-in features like over current protection (OPC) test and over power protection (OPP) test and dynamic constant current waveform testing, new power supply designs can be thoroughly evaluated against design specifications. An analog input mode allows arbitrary current waveforms to be applied to a unit under test as well.
Battery Charge/Discharge Testing
Time sequencing of specific discharge current levels as a function of battery voltage allows characterization and performance testing of various battery chemistries. The high current resolution and accuracy of the 5VP Series load supports testing of both small and large batteries.
Solar Panel Loading
The maximum power point tracking function of the 5VP DC loads simulate the behavior of a solar inverter allowing solar panel testing under a variety of conditions.