EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch
  • innerBanner2
  • innerBanner1
  • innerBanner3
  • Inquiry(0)
  • 繁體中文
  • English
  • 简体中文
  • Home
  • About Us
    • PROFILE
    • MAIN BUSINESS
  • Products
    • EM TEST
    • WEETECH
    • PACIFIC POWER SOURCE
    • SYSTEM INTEGRATION
  • Hot Products
  • News
    • EXCENTECH NEWS
    • PRODUCT NEWS
  • Contact Us
    • CONTACT FORM
    • LOCATION
Home » Products » PACIFIC POWER SOURCE » APS » AC & DC Loads »

3B Series PROGRAMMABLE AC & DC LOADS

PACIFIC POWER SOURCE

  • EM TEST
    • Automotive EMC Test Solutions
    • ESD Simulators
    • EMS Compact Generators
    • Voltage Surge Generators
    • Telecom Surge Generators
    • Conducted LF/RF Immunity Testing
    • Harmonics & Flicker
  • WEETECH
    • Low Voltage Cable Test
    • High Voltage Cable Test
    • Functional Test
    • Backplane/Chassis Test
  • PACIFIC POWER SOURCE
    • PPST
      • AMX Series
      • ACX Series
      • ASX Series
      • AFX Series
      • MS Series
      • G Series
    • APS
      • AC & DC Loads
      • AC & AC Sources
      • APS Software
    • STS
      • Battery Element Testers
      • Model 1740 Test System
    • ZENONE
      • GI Series
      • GI -SI Series
      • GIS Series
      • GV Series
      • GTS Series
      • FVC Series
      • AL3000 Series
      • AL3000R Series
  • SYSTEM INTEGRATION
    • CISPR 25 Radiation & Conduction Measurement
    • ISO 10605 Electrostatic Discharge (ESD)
    • ISO 7637-2: Electrical transient conduction along supply lines only
      • Transient emission
      • Transient Immunity
        • Pulse 1
        • Pulse 2a
        • Pulse 3a/3b
        • Pulse 2b
        • Pulse 4
        • Pulse 5
    • ISO 7637-3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    • ISO 16750-2: Environmental conditions and testing
    • ISO 11452-2: Absorber-lined shielded enclosure
    • ISO 11452-4: Harness excitation methods (Including BCI method)
    • ISO 11452-5: Stripline
    • ISO 11452-8: Immunity to magnetic fields
    • ISO 11452-9: Portable Transmitters testing

3B Series PROGRAMMABLE AC & DC LOADS

  • 3B Series PROGRAMMABLE AC & DC LOADS 1
  • 3B Series PROGRAMMABLE AC & DC LOADS 2
  • 3B Series PROGRAMMABLE AC & DC LOADS 3

Model : 3B Series

Q'ty :

Add To Inquiry

  • 3B Series PROGRAMMABLE AC & DC LOADS
  • Description
  • Specifications
  • Features
  • Applications

The 3B Series DC loads comprises a range of medium to high power AC and DC capable load systems with support for up to 300Vrms input voltages.

All loads share a common user interface. Packaged in a compact 19” 4U chassis, 3B Series loads support up to 1800 VA per chassis. For higher power requirements, 3B Series load cabinets consisting of one master and one or more slaves units support power levels from 2400 VA to 12.6 kVA. These integrated cabinet systems operate from a single user control panel or remote control interface.

For questions regarding the 3B Series DC Loads, please contact us.

The Adaptive Power 3B Series loads are intended for medium to high power AC or DC test and product development applications in a wide range of industries. The 3B Series models support voltages to 300Vrms and are well suited for testing AC Sources and DC/AC inverters. Their flexible V-I operating curves span range of voltage and current combinations at any given power level. All 3B Series models have a low range mode for enhanced accuracy and resolution at lower voltage and current levels, further increasing their effectiveness.

The 3B Series consists of a total of nine different models up to 12.6kVA providing a wide variation of possible voltage, current and power combinations. For higher power AC or DC requirements, multiple 3B cabinets can be paralleled as needed.

Model 3B012-12 3B018-18 3B024-24 3B036-36 3B054-54
OPERATING RANGES
Power Ranges 0 – 1200 VA 0 – 1800 VA 0 – 2400 VA 0 – 3600 VA 0 – 5400 VA
Current Ranges 0 -6 A 6 – 12 A 0 – 9 A 9 – 18 A 0 – 12 A 12 – 24 A 0 – 18 A 18 – 36 A 0-27A 27-54A
Voltage Range 50 – 300
Vrms/Vdc
50 – 300 Vrms/Vdc 50 – 300 Vrms/Vdc 50 – 300 Vrms/Vdc 50 – 300 Vrms/Vdc
Frequency DC, 40 – 400Hz  (CC Mode) / DC – 400Hz (LIN,CR  Mode)
OPERATING MODES Constant Current (CC), Linear CC (LCC), Constant Resistance (CR), CREST FACTOR (CF) (in CC Mode only)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
CREST & POWER FACTOR RANGE
Lagging PF CF: √2 to 3.5 . PF: – 0.30 to -0.85
Leading PF CF: √2 to 3.5 . PF: + 0.30 to +0.85 or 1.00
METERING
Voltage Range 0 – 300 V
Current Range 0 – 12 A 0 – 18 A 0 – 24 A 0 – 36 A 0 – 54 A
Power Range 0 – 1200 W 0 – 1800 W 0 – 2400 W 0 – 3600 W 0 – 5400 W
VA Range 0 – 1200 W 0 – 1800 W 0 – 2400 W 0 – 3600 W 0 – 5400 W
OTHER SPECIFICATIONS
Current Monitor 3 A/V 4.5 A/V 6 A/V 9 A/V 13.5 A/V
Dimensions (HxWxD) 177 x 440 x 445 mm
7.0″ x 17.2″ x 17.5″
839 x 600 x 600 mm
33″ x 23.6″ x 23.6″
Weight (Net, Module) 18.5kg / 40.8 lbs 21.5kg / 47.4 lbs 77.0kg / 169.8 lbs 77.0kg / 169.8 lbs 98.5kg / 217.2 lbs
Model 3B072-72 3B090-90 3B108-108 3B126-126
OPERATING RANGES
Power Ranges 0 – 7200 VA 0 – 9000 VA 0 – 10800 VA 0 – 12600 VA
Current Ranges 0 -36 A 36 – 72 A 0 – 45 A 45 – 90 A 0 – 54 A 54 – 108 A 0 – 63 A 63 – 126 A
Voltage Range 50 – 300 Vrms/Vdc 50 – 300 Vrms/Vdc 50 – 300 Vrms/Vdc 50 – 300 Vrms/Vdc
Frequency DC, 40 – 400Hz  (CC Mode) / DC – 400Hz (LIN,CR  Mode)
OPERATING MODES Constant Current (CC), Linear CC (LCC), Constant Resistance (CR), CREST FACTOR (CF) (in CC Mode only)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
CREST & POWER FACTOR RANGE
Lagging PF CF: √2 to 3.5 . PF: – 0.30 to -0.85
Leading PF CF: √2 to 3.5 . PF: + 0.30 to +0.85 or 1.00
METERING
Voltage Range 0 – 300 V
Current Range 0 – 72 A 0 – 90 A 0 – 108 A 0 – 126 A
Power Range 0 – 7200 W 0 – 9000 W 0 – 10800 W 0 – 12600 W
VA Range 0 – 7200 W 0 – 9000 W 0 – 10800 W 0 – 12600 W
OTHER SPECIFICATIONS
Current Monitor 3 A/V 4.5 A/V 6 A/V 9 A/V
Dimensions (HxWxD) 1283 x 600 x 600 mm
50.5″ x 23.6″ x 23.6″
1506 x 600 x 600 mm
59.3″ x 23.6″ x 23.6″
1728 x 600 x 600 mm
68″ x 23.6″ x 23.6″
Weight (Net, Module) 153.0kg / 337.3 lbs 174.5kg / 384.7 lbs 196.0kg / 432.1 lbs 230.5kg / 508.2 lbs
1200VA or 1800VA per Chassis
Up to 12,600VA per Cabinet
Voltage Range, 300Vrms
Current Ranges up to 126A per cabinet
High-Speed 4½  Digit Precision Metering Capability
Parallel Operation for High Power Applications
AC Current Monitor Output Signal
Operating Modes: Constant Current (CC), Linear Constant Current (LCC), Constant Resistance (CR) and Crest Factor (CF) control
Leading and Lagging Power Factor (PF)
Over Current Protection Test Mode
Over Power Protection Test Mode
Conventional and Linear CC Modes
RS232 and GPIB Interfaces
CE Mark
Load Versatility

All APS 3B Series Loads are equipped with a powerful microcontroller and user friendly controls to provide capabilities that cover a wide range of load applications. Precision metering of Voltage, Current, Power and Resistance is standard.

AC Power Source Testing (AC Mode)

Elaborate testing of linear and switch mode AC Sources, DC/AC inverters or Frequency changers is made possible by flexible ranging and wide V-I operating curves found in all 3B Series APS loads. This supports extensive production test and burn-in of AC power supplies.

AC Power Source Design (AC Mode)

With built-in features like over current protection (OPC) test and over power protection (OPP) test and Power and Crest Factor control and non-sinusoidal waveform testing, new AC power source designs can be thoroughly evaluated against design specifications. An analog input mode allows arbitrary current waveforms to be applied to a unit under test as well.

Battery Charge/Discharge Testing (DC Mode)

Using the DC load mode, specific discharge current levels can be set as a function of battery voltage. This allows characterization and performance testing of various battery chemistries. AC/DC supplies and converters can be tested in DC mode as well.
Related Products
5VP Series HIGH POWER PROGRAMMABLE DC LOADS

5VP Series HIGH POWER PROGRAMMABLE DC LOADS

Model : 5VP Series
5 Series COMPACT PROGRAMMABLE DC LOADS

5 Series COMPACT PROGRAMMABLE DC LOADS

Model : 5 Series
4 Series MODULAR DC LOADS

4 Series MODULAR DC LOADS

Model : 4 Series
3A Series MODULAR AC & DC LOADS

3A Series MODULAR AC & DC LOADS

Model : 3A Series

Products

  • EM TEST
  • WEETECH
  • PACIFIC POWER SOURCE
  • SYSTEM INTEGRATION

Navigation

  • About Us
  • Products
  • Hot Products
  • News
  • Contact Us
  • Site Map
  • Privacy Policy

Contact Us

  • TEL: 886-2-29178080
  • FAX: 886-2-29172626
  • Email: sales@excen-tech.com
  • Address:
    3F-2, No. 92, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan

© 2025 EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch All rights reserved.