4 Series MODULAR DC LOADS
The 4 Series modular DC loads allow multi-channel load systems to be configured with easy.
Available load modules range from single channel and dual channel to application specific LED simulator modules. Mainframes in the 4 Series can accommodate 1, 2 or 4 modules with a maximum 1200W of DC load capability and up to 8 loads per mainframe.
If you can’t find what you are looking for on these product pages, contact us by phone or email to discuss your application requirements with one of our power specialist.
The Adaptive Power 4 Series of Programmable DC Electronic Load Modules are ideally suited for testing multiple output AC/DC power supplies, DC/DC converters, battery chargers, LEDlighting power supplies and other power products.
The high power density of the 4 Series allows up to 8 loads to be installed in a single 19″ wide rack-mount mainframe. For lesser demands, mainframes with two slots or a single slot are available as well.
The 4 Series consists of a total of 12 different modules types providing a wide variation of possible voltage, current, power and feature choices. Starting at 75 Watt and ranging to 300 Watt per module, all modules offer dual range capability for optimal accuracy and resolution. Voltage ranges start at 60Vdc and extend up to 500Vdc. Special LED simulation loads are available for lighting applications up to 500Vdc. (41D/42D Models)
Note: For voltage requirements up to 600Vdc on 4 Series loads, contact factory for special quote.
Single Channel Modules
Model | 41L0630 | 41L0660 | 41L2512 | 41L5012 | 41L0615 | |||||
---|---|---|---|---|---|---|---|---|---|---|
OPERATING RANGES | ||||||||||
Power Ranges | 0 – 15 W | 0 – 150 W | 0 – 30 W | 0 – 300 W | 0 – 30 W | 0 – 300 W | 0 – 30 W | 0 – 300 W | 0 – 7.5 W | 0 – 75 W |
Current Ranges | 0 – 3 A | 0 – 30 A | 0 – 6 A | 0 – 60 A | 0 – 1.2 A | 0 – 12 A | 0 – 1.2 A | 0 – 12 A | 0 – 1.5 A | 0 – 15 A |
Voltage Range | 60 V | 60 V | 250 V | 500 V | 60 V | |||||
Minimum Voltage | 0.6V @ 30A | 0.6V @ 60A | 1.0V @ 12A | 6.0V @ 12A | 0.3V @ 15A | |||||
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP) | |||||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||||||
DYNAMIC OPERATION |
||||||||||
T high & T low | 50 μsec TO 9.999s (20 kHz) | |||||||||
Slew Rate | 2.0 – 125 mA / μsec | 20 – 1250 mA / μsec | 4 – 250 mA / μsec | 40 – 2500 mA / μsec | 8 – 50 mA / μsec | 8 – 500 mA / μsec | 0.8 – 50 mA / μsec | 8.0 – 500 mA / μsec | 1.0 – 62.5 mA / μsec | 10.0 – 625 mA / μsec |
METERING | ||||||||||
Voltage Read – back Ranges | 0 – 6.0 V | 0 – 60.0 V | 0 – 60.0 V | 0 – 60.0 V | 0 – 30.0 V | 0 – 250 V | 0 – 60.0 V | 0 – 500 V | 0 – 6.0 V | 0 – 6.0 V |
Current Read – back Ranges | 0 – 3.0 A | 0 – 30.0 A | 0 – 6.0 A | 0 – 60.0 A | 0 – 1.2 A | 0 – 12.0 A | 0 – 1.2 A | 0 – 12.0 A | 0 – 1.5 A | 0 – 15.0 A |
SHORT CIRCUIT | ||||||||||
Programmable Short | BUILT – IN | |||||||||
Max. Short Current | 30 A | 60 A | 12 A | 12 A | 15 A |
Dual Channel Modules
Model | 42L0860 | 42L0824 | 40L0803 | |||
---|---|---|---|---|---|---|
OPERATING RANGES | ||||||
Power Ranges | 0 – 25W / 0 – 250W | 0 – 5W / 0 – 50W | 0 – 12W / 0 – 120W | 0 – 12W / 0 – 120 W | 0 – 4 W / 0 – 40 W | 0 – 4 W / 0 – 40 W |
Current Ranges | 0 – 3 A | 0 – 30 A | 0 – 6 A | 0 – 60 A | 0 – 1.2 A | 0 – 12 A |
Voltage Range | 0 – 80 V | 0 – 80 V | 0 – 80 V | 0 – 80 V | 0 – 80 V | 0 – 80 V |
Minimum Voltage | 0.8 V @ 60 A | 0.8 V @ 6 A | 0.8 V @ 24 A | 0.8 V @ 24 A | 0.3 V @ 3 A | 0.3 V @ 3 A |
OPERATING MODES | Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP) | |||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||
DYNAMIC OPERATION |
||||||
T high & T low | 0.050 – 9.999 / 99.99 / 999.9 / 9999ms (20 kHz) | |||||
Slew Rate | 4mA – 250mA/μs | 0.4mA – 25mA/μs | 1.6mA – 100mA/μs | 0.2mA – 12.5mA/μs | ||
Slew Rate | 40mA – 2500mA/μs | 4mA – 250mA/μs | 16mA – 1000mA/μs | 2mA – 125mA/μs | ||
METERING | ||||||
Voltage Read – back Ranges | 0 – 6 V / 0 – 81 V | |||||
Current Read – back Ranges | 0 – 6.0A / 0 – 60.0A | 0 – 0.6A / 0 – 6.0A | 0 – 2.4 A / 0 – 24.0 A | 0 – 0.3 A / 0 – 3.0 A | ||
Power Read – back Ranges | 0 – 250.0 W | 0 – 50.0 W | 0 – 120.0 W | 0 – 40.0 W | ||
MAX. SHORT CURRENT | 60 A | 6 A | 24 A | 3 A |
LED Modules
Model | 41D3024 | 41D5012 | 41D5024 | 42D5006 | ||||
---|---|---|---|---|---|---|---|---|
OPERATING RANGES | ||||||||
Power Ranges | 0 – 300 W | 0 – 300 W | 0 – 300 W | 0 – 150 W | 0 – 150 W | |||
Current Ranges | 0 – 6 A | 0 – 24 A | 0 – 6 A | 0 – 12 A | 0 – 6 A | 0 – 24 A | 0 – 1.5A/0 – 6A | 0 – 1.5A/0 – 6A |
Voltage Range (1) | 0 – 300 V | 0 – 500 V | 0 – 500 V | 0 – 500 V | 0 – 500 V | |||
Minimum Voltage | 3 V @ 24 A | 6 V @ 12 A | 6 V @ 24 A | 4 V @ 6 A | 4 V @ 6 A | |||
OPERATING MODES | LED, Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP) | LED, CC, CR, CV | ||||||
PROTECTION | Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT) | |||||||
DYNAMIC OPERATION |
||||||||
T high & T low | 0.050 / 9.999 / 99.99 / 999.9 / 9999 ms (20 kHz) | N/A | ||||||
Slew Rate | 4.8 – 300 mA /μs | 19.2 – 1200 mA /μs | 2.4 – 150 mA /μs | 9.6 – 600 mA /μs | 4.8 – 300 mA /μs | 19.2 – 1200 mA /μs | N/A | |
METERING | ||||||||
Voltage Read – back Ranges | 0 – 30V/0 – 150V/0 – 300V | 0 – 60V/0 – 300V/0 – 600V | 0 – 60V/0 – 300V/0 – 600V | 0 – 60V/0 – 300V/0 – 600V | ||||
Current Read – back Ranges | 0 – 6.0 A | 0 – 24 A | 0 – 3.0 A | 0 – 12 A | 0 – 6.0 A | 0 – 24 A | 0 – 1.5A/0 – 6A | 0 – 1.5A/0 – 6A |
Power Read – back Ranges | 0 – 300.0 W | 0 – 300.0 W | 0 – 300.0 W | 0 – 300.0 W | ||||
DIMMING CONTROL | Range: 0 – 12 V / Freq Range: DC – 1KHz / Duty Cycle: 1% – 99% | |||||||
SHORT SIGNAL OUTPUT | 12 V / 100 mA max |
Note (1): For voltage requirements up to 600Vdc on 4 Series loads, contact factory for special quote.
Mainframes
Mainframe | 44M01 | 44M02 | 44M04 | |
---|---|---|---|---|
No. of Slots | 1 | 2 | 4 | |
Supports |
41L0630, 41L0660, 41L2512, 41:5012, 41L0616 42L0860, 42L0824, 42L0803 41D3024, 41D5012, 41D5024, 42D5006 |
|||
Max Po Wer | 300 W | 600 W | 1200 W | |
AC Input | 100-115Vac ±10% or 200-230Vac ±10% | |||
Frequency | 50 / 60 Hz ±3Hz | |||
Po Wer (max.) | 40 W | 60 W | 150 W | |
Dimensions (Hx WxD) |
177 x 160 x 452mm 7.0 x 6.3 x 17.8″ |
177 x 269 x 452mm 7.0 x 10.6 x 17.8″ |
177 x 440 x 445mm 7.0 x 17.3 x 17.5″ |
|
Weight | 5.5 kg / 12.2 lbs | 7.5 kg / 16.5 lbs | 9.3 kg / 20.5 lbs |
Extended Voltage Range, 0 – 500 Vdc
Max. Current Range 60 Adc
Single Load, Dual Load and LED Load Modules Available
Up to 8 Load Inputs per Mainframe
Parallel Modules to 1200W
Synchronized Operation of Multiple Loads
Special LED Load Models available for lighting applications
Operating Modes: CC, CP, CR, CV and LED
Built-in Short Circuit Test
Over Current Protection Test Mode
Over Power Protection Test Mode
Static and Dynamic CC Modes
Available Interface Options are USB, RS232, GPIB and LAN
CE Mark
All ASP 4 Series Loads are equipped with a powerful microcontroller and user friendly controls to provide capabilities that cover a wide range of load applications. Built in metering of Voltage, Current, Power and Resistance.
Power Supply Testing
With a range of up to 8 load channels, the 42L load modules support testing for multiple output power supplies and AC/DC converters. The ability to load all outputs simultaneously of to test up to eight single output DC supplies at once provides significant test throughput in high voltage production environments.
Power Supply Design
With built-in features like over current protection (OPC) test and over power protection (OPP) test and dynamic constant current waveform testing, new power supply designs can be thoroughly evaluated against design specifications. An analog input mode allows arbitrary current waveforms to be applied to a unit under test as well.
Battery Charge/Discharge Testing
Time sequencing of specific discharge current levels as a function of battery voltage allows characterization and performance testing of various battery chemistries. The high current resolution and accuracy of the 4 Series load modules supports testing of very small batteries for portable device applications.
LED Lighting
The 41D and 42D load modules are specially designed to support LED lighting applications by allowing accuracy simulation of LED load characteristic to be simulated. These modules simulate an LED V-I curve based on Vd and Rd input settings. For dimming LED supply development and test, the 41D and 42D modules include a PWM dimming output signal with programmable duty cycle and frequency. Recently updated with higher current support levels, multiple voltage ranges for higher accuracy and resolution, the 41D/42D LED loads offer the best price performance for lighting applications available.