EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch
  • innerBanner2
  • innerBanner1
  • innerBanner3
  • Inquiry(0)
  • 繁體中文
  • English
  • 简体中文
  • Home
  • About Us
    • PROFILE
    • MAIN BUSINESS
  • Products
    • EM TEST
    • WEETECH
    • PACIFIC POWER SOURCE
    • SYSTEM INTEGRATION
  • Hot Products
  • News
    • EXCENTECH NEWS
    • PRODUCT NEWS
  • Contact Us
    • CONTACT FORM
    • LOCATION
Home » Products » PACIFIC POWER SOURCE » APS » AC & DC Loads »

4 Series MODULAR DC LOADS

PACIFIC POWER SOURCE

  • EM TEST
    • Automotive EMC Test Solutions
    • ESD Simulators
    • EMS Compact Generators
    • Voltage Surge Generators
    • Telecom Surge Generators
    • Conducted LF/RF Immunity Testing
    • Harmonics & Flicker
  • WEETECH
    • Low Voltage Cable Test
    • High Voltage Cable Test
    • Functional Test
    • Backplane/Chassis Test
  • PACIFIC POWER SOURCE
    • PPST
      • AMX Series
      • ACX Series
      • ASX Series
      • AFX Series
      • MS Series
      • G Series
    • APS
      • AC & DC Loads
      • AC & AC Sources
      • APS Software
    • STS
      • Battery Element Testers
      • Model 1740 Test System
    • ZENONE
      • GI Series
      • GI -SI Series
      • GIS Series
      • GV Series
      • GTS Series
      • FVC Series
      • AL3000 Series
      • AL3000R Series
  • SYSTEM INTEGRATION
    • CISPR 25 Radiation & Conduction Measurement
    • ISO 10605 Electrostatic Discharge (ESD)
    • ISO 7637-2: Electrical transient conduction along supply lines only
      • Transient emission
      • Transient Immunity
        • Pulse 1
        • Pulse 2a
        • Pulse 3a/3b
        • Pulse 2b
        • Pulse 4
        • Pulse 5
    • ISO 7637-3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    • ISO 16750-2: Environmental conditions and testing
    • ISO 11452-2: Absorber-lined shielded enclosure
    • ISO 11452-4: Harness excitation methods (Including BCI method)
    • ISO 11452-5: Stripline
    • ISO 11452-8: Immunity to magnetic fields
    • ISO 11452-9: Portable Transmitters testing

4 Series MODULAR DC LOADS

  • 4 Series MODULAR DC LOADS 1
  • 4 Series MODULAR DC LOADS 2
  • 4 Series MODULAR DC LOADS 3

Model : 4 Series

Q'ty :

Add To Inquiry

  • 4 Series MODULAR DC LOADS
  • Description
  • Specifications
  • Features
  • Applications

The 4 Series modular DC loads allow multi-channel load systems to be configured with easy.

Available load modules range from single channel and dual channel to application specific LED simulator modules. Mainframes in the 4 Series can accommodate 1, 2 or 4 modules with a maximum 1200W of DC load capability and up to 8 loads per mainframe.

If you can’t find what you are looking for on these product pages, contact us by phone or email to discuss your application requirements with one of our power specialist.

The Adaptive Power 4 Series of Programmable DC Electronic Load Modules are ideally suited for testing multiple output AC/DC power supplies, DC/DC converters, battery chargers, LEDlighting power supplies and other power products.

The high power density of the 4 Series allows up to 8 loads to be installed in a single 19″ wide rack-mount mainframe. For lesser demands, mainframes with two slots or a single slot are available as well.

The 4 Series consists of a total of 12 different modules types providing a wide variation of possible voltage, current, power and feature choices. Starting at 75 Watt and ranging to 300 Watt per module, all modules offer dual range capability for optimal accuracy and resolution. Voltage ranges start at 60Vdc and extend up to 500Vdc. Special LED simulation loads are available for lighting applications up to 500Vdc. (41D/42D Models)
Note: For voltage requirements up to 600Vdc on 4 Series loads, contact factory for special quote.

Single Channel Modules
Model 41L0630 41L0660 41L2512 41L5012 41L0615
OPERATING RANGES
Power Ranges 0 – 15 W 0 – 150 W 0 – 30 W 0 – 300 W 0 – 30 W 0 – 300 W 0 – 30 W 0 – 300 W 0 – 7.5 W 0 – 75 W
Current Ranges 0 – 3 A 0 – 30 A 0 – 6 A 0 – 60 A 0 – 1.2 A 0 – 12 A 0 – 1.2 A 0 – 12 A 0 – 1.5 A 0 – 15 A
Voltage Range 60 V 60 V 250 V 500 V 60 V
Minimum Voltage 0.6V @ 30A 0.6V @ 60A 1.0V @ 12A 6.0V @ 12A 0.3V @ 15A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 50 μsec TO 9.999s (20 kHz)
Slew Rate 2.0 – 125 mA / μsec 20 – 1250 mA / μsec 4 – 250 mA / μsec 40 – 2500 mA / μsec 8 – 50 mA / μsec 8 – 500 mA / μsec 0.8 – 50 mA / μsec 8.0 – 500 mA / μsec 1.0 – 62.5 mA / μsec 10.0 – 625 mA / μsec
METERING
Voltage Read – back Ranges 0 – 6.0 V 0 – 60.0 V 0 – 60.0 V 0 – 60.0 V 0 – 30.0 V 0 – 250 V 0 – 60.0 V 0 – 500 V 0 – 6.0 V 0 – 6.0 V
Current Read – back Ranges 0 – 3.0 A 0 – 30.0 A 0 – 6.0 A 0 – 60.0 A 0 – 1.2 A 0 – 12.0 A 0 – 1.2 A 0 – 12.0 A 0 – 1.5 A 0 – 15.0 A
SHORT CIRCUIT
Programmable Short BUILT – IN
Max. Short Current 30 A 60 A 12 A 12 A 15 A
Dual Channel Modules
Model 42L0860 42L0824 40L0803
OPERATING RANGES
Power Ranges 0 – 25W / 0 – 250W 0 – 5W / 0 – 50W 0 – 12W / 0 – 120W 0 – 12W / 0 – 120 W 0 – 4 W / 0 – 40 W 0 – 4 W / 0 – 40 W
Current Ranges 0 – 3 A 0 – 30 A 0 – 6 A 0 – 60 A 0 – 1.2 A 0 – 12 A
Voltage Range 0 – 80 V 0 – 80 V 0 – 80 V 0 – 80 V 0 – 80 V 0 – 80 V
Minimum Voltage 0.8 V @ 60 A 0.8 V @ 6 A 0.8 V @ 24 A 0.8 V @ 24 A 0.3 V @ 3 A 0.3 V @ 3 A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050 – 9.999 / 99.99 / 999.9 / 9999ms (20 kHz)
Slew Rate 4mA – 250mA/μs 0.4mA – 25mA/μs 1.6mA – 100mA/μs 0.2mA – 12.5mA/μs
Slew Rate 40mA – 2500mA/μs 4mA – 250mA/μs 16mA – 1000mA/μs 2mA – 125mA/μs
METERING
Voltage Read – back Ranges 0 – 6 V / 0 – 81 V
Current Read – back Ranges 0 – 6.0A / 0 – 60.0A 0 – 0.6A / 0 – 6.0A 0 – 2.4 A / 0 – 24.0 A 0 – 0.3 A / 0 – 3.0 A
Power Read – back Ranges 0 – 250.0 W 0 – 50.0 W 0 – 120.0 W 0 – 40.0 W
MAX. SHORT CURRENT 60 A 6 A 24 A 3 A
LED Modules
Model 41D3024 41D5012 41D5024 42D5006
OPERATING RANGES
Power Ranges 0 – 300 W 0 – 300 W 0 – 300 W 0 – 150 W 0 – 150 W
Current Ranges 0 – 6 A 0 – 24 A 0 – 6 A 0 – 12 A 0 – 6 A 0 – 24 A 0 – 1.5A/0 – 6A 0 – 1.5A/0 – 6A
Voltage Range (1) 0 – 300 V 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V
Minimum Voltage 3 V @ 24 A 6 V @ 12 A 6 V @ 24 A 4 V @ 6 A 4 V @ 6 A
OPERATING MODES LED, Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP) LED, CC, CR, CV
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050 / 9.999 / 99.99 / 999.9 / 9999 ms (20 kHz) N/A
Slew Rate 4.8 – 300 mA /μs 19.2 – 1200 mA /μs 2.4 – 150 mA /μs 9.6 – 600 mA /μs 4.8 – 300 mA /μs 19.2 – 1200 mA /μs N/A
METERING
Voltage Read – back Ranges 0 – 30V/0 – 150V/0 – 300V 0 – 60V/0 – 300V/0 – 600V 0 – 60V/0 – 300V/0 – 600V 0 – 60V/0 – 300V/0 – 600V
Current Read – back Ranges 0 – 6.0 A 0 – 24 A 0 – 3.0 A 0 – 12 A 0 – 6.0 A 0 – 24 A 0 – 1.5A/0 – 6A 0 – 1.5A/0 – 6A
Power Read – back Ranges 0 – 300.0 W 0 – 300.0 W 0 – 300.0 W 0 – 300.0 W
DIMMING CONTROL Range: 0 – 12 V / Freq Range: DC – 1KHz / Duty Cycle: 1% – 99%
SHORT SIGNAL OUTPUT 12 V / 100 mA max

Note (1): For voltage requirements up to 600Vdc on 4 Series loads, contact factory for special quote.

Mainframes
Mainframe 44M01 44M02 44M04
No. of Slots 1 2 4
Supports 41L0630, 41L0660, 41L2512, 41:5012, 41L0616
42L0860, 42L0824, 42L0803
41D3024, 41D5012, 41D5024, 42D5006
Max Po Wer 300 W 600 W 1200 W
AC Input 100-115Vac ±10% or 200-230Vac ±10%
Frequency 50 / 60 Hz ±3Hz
Po Wer (max.) 40 W 60 W 150 W
Dimensions (Hx WxD) 177 x 160 x 452mm
7.0 x 6.3 x 17.8″
177 x 269 x 452mm
7.0 x 10.6 x 17.8″
177 x 440 x 445mm
7.0 x 17.3 x 17.5″
Weight 5.5 kg / 12.2 lbs 7.5 kg / 16.5 lbs 9.3 kg / 20.5 lbs
Max. Power 300W per Module
Extended Voltage Range, 0 – 500 Vdc
Max. Current Range 60 Adc
Single Load, Dual Load and LED Load Modules Available
Up to 8 Load Inputs per Mainframe
Parallel Modules to 1200W
Synchronized Operation of Multiple Loads
Special LED Load Models available for lighting applications
Operating Modes: CC, CP, CR, CV and LED
Built-in Short Circuit Test
Over Current Protection Test Mode
Over Power Protection Test Mode
Static and Dynamic CC Modes
Available Interface Options are USB, RS232, GPIB and LAN
CE Mark
Load Versatility

All ASP 4 Series Loads are equipped with a powerful microcontroller and user friendly controls to provide capabilities that cover a wide range of load applications. Built in metering of Voltage, Current, Power and Resistance.

Power Supply Testing

With a range of up to 8 load channels, the 42L load modules support testing for multiple output power supplies and AC/DC converters. The ability to load all outputs simultaneously of to test up to eight single output DC supplies at once provides significant test throughput in high voltage production environments.

Power Supply Design

With built-in features like over current protection (OPC) test and over power protection (OPP) test and dynamic constant current waveform testing, new power supply designs can be thoroughly evaluated against design specifications. An analog input mode allows arbitrary current waveforms to be applied to a unit under test as well.

Battery Charge/Discharge Testing

Time sequencing of specific discharge current levels as a function of battery voltage allows characterization and performance testing of various battery chemistries. The high current resolution and accuracy of the 4 Series load modules supports testing of very small batteries for portable device applications.

LED Lighting

The 41D and 42D load modules are specially designed to support LED lighting applications by allowing accuracy simulation of LED load characteristic to be simulated. These modules simulate an LED V-I curve based on Vd and Rd input settings. For dimming LED supply development and test, the 41D and 42D modules include a PWM dimming output signal with programmable duty cycle and frequency. Recently updated with higher current support levels, multiple voltage ranges for higher accuracy and resolution, the 41D/42D LED loads offer the best price performance for lighting applications available.
Related Products
3B Series PROGRAMMABLE AC & DC LOADS

3B Series PROGRAMMABLE AC & DC LOADS

Model : 3B Series
3A Series MODULAR AC & DC LOADS

3A Series MODULAR AC & DC LOADS

Model : 3A Series
5 Series COMPACT PROGRAMMABLE DC LOADS

5 Series COMPACT PROGRAMMABLE DC LOADS

Model : 5 Series
5VP Series HIGH POWER PROGRAMMABLE DC LOADS

5VP Series HIGH POWER PROGRAMMABLE DC LOADS

Model : 5VP Series

Products

  • EM TEST
  • WEETECH
  • PACIFIC POWER SOURCE
  • SYSTEM INTEGRATION

Navigation

  • About Us
  • Products
  • Hot Products
  • News
  • Contact Us
  • Site Map
  • Privacy Policy

Contact Us

  • TEL: 886-2-29178080
  • FAX: 886-2-29172626
  • Email: sales@excen-tech.com
  • Address:
    3F-2, No. 92, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan

© 2025 EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch All rights reserved.