EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch
  • innerBanner2
  • innerBanner1
  • innerBanner3
  • Inquiry(0)
  • 繁體中文
  • English
  • 简体中文
  • Home
  • About Us
    • PROFILE
    • MAIN BUSINESS
  • Products
    • EM TEST
    • WEETECH
    • PACIFIC POWER SOURCE
    • SYSTEM INTEGRATION
  • Hot Products
  • News
    • EXCENTECH NEWS
    • PRODUCT NEWS
  • Contact Us
    • CONTACT FORM
    • LOCATION
Home » Products » PACIFIC POWER SOURCE » APS » AC & DC Loads »

5 Series COMPACT PROGRAMMABLE DC LOADS

PACIFIC POWER SOURCE

  • EM TEST
    • Automotive EMC Test Solutions
    • ESD Simulators
    • EMS Compact Generators
    • Voltage Surge Generators
    • Telecom Surge Generators
    • Conducted LF/RF Immunity Testing
    • Harmonics & Flicker
  • WEETECH
    • Low Voltage Cable Test
    • High Voltage Cable Test
    • Functional Test
    • Backplane/Chassis Test
  • PACIFIC POWER SOURCE
    • PPST
      • AMX Series
      • ACX Series
      • ASX Series
      • AFX Series
      • MS Series
      • G Series
    • APS
      • AC & DC Loads
      • AC & AC Sources
      • APS Software
    • STS
      • Battery Element Testers
      • Model 1740 Test System
    • ZENONE
      • GI Series
      • GI -SI Series
      • GIS Series
      • GV Series
      • GTS Series
      • FVC Series
      • AL3000 Series
      • AL3000R Series
  • SYSTEM INTEGRATION
    • CISPR 25 Radiation & Conduction Measurement
    • ISO 10605 Electrostatic Discharge (ESD)
    • ISO 7637-2: Electrical transient conduction along supply lines only
      • Transient emission
      • Transient Immunity
        • Pulse 1
        • Pulse 2a
        • Pulse 3a/3b
        • Pulse 2b
        • Pulse 4
        • Pulse 5
    • ISO 7637-3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    • ISO 16750-2: Environmental conditions and testing
    • ISO 11452-2: Absorber-lined shielded enclosure
    • ISO 11452-4: Harness excitation methods (Including BCI method)
    • ISO 11452-5: Stripline
    • ISO 11452-8: Immunity to magnetic fields
    • ISO 11452-9: Portable Transmitters testing

5 Series COMPACT PROGRAMMABLE DC LOADS

  • 5 Series COMPACT PROGRAMMABLE DC LOADS 1
  • 5 Series COMPACT PROGRAMMABLE DC LOADS 2
  • 5 Series COMPACT PROGRAMMABLE DC LOADS 3
  • 5 Series COMPACT PROGRAMMABLE DC LOADS 4
  • 5 Series COMPACT PROGRAMMABLE DC LOADS 5
  • 5 Series COMPACT PROGRAMMABLE DC LOADS 6

Model : 5 Series

Q'ty :

Add To Inquiry

  • 5 Series COMPACT PROGRAMMABLE DC LOADS
  • 5 Series COMPACT PROGRAMMABLE DC LOADS 1
  • 5 Series COMPACT PROGRAMMABLE DC LOADS 2
  • Description
  • Specifications
  • Features
  • Applications

The 5 Series DC loads comprises a range of medium to high power DC load systems with support for 60V or 500V input ranges.

All loads share a common user interface. Packaged in a compact 19” 4U chassis, 5 Series loads support up to 1800W. For higher power requirements, 5 Series load cabinets consisting of one master and one or more slaves units support power levels from 2400W to 14.4kW. These integrated cabinet systems operate from a single user control panel or remote control interface.

There are fourdifferent model 5 Series: 5D (LED Loads), 5L (60V to 1800W), 5P (60V to 14.4kW) and 5V (500V to 14.4kW).

For questions regarding the 5 Series DC Loads, please contact us.

The Adaptive Power 5 Series loads are intended for medium to high power DC test and product development applications in a wide range of industries. The 5L and 5P Series models support voltages to 60V and are well suited for testing 12V, 24V or 48V batteries. Their flexible V-I operating curves span range of voltage and current combinations at any given power level. All 5 Series models have a low range mode for enhanced accuracy and resolution at lower voltage and current levels, further increasing their effectiveness.

For higher voltage applications, the 5V Series supports voltage inputs to 500Vdc. This covers large battery packs used for EV and HEV vehicle power as well as energy storage systems found in Solar and Wind power applications.

The 5D Series models are special LED loads designed to support development and test of LED drivers. These loads simulate various combinations of LED and their electrical characteristics.

The 5 Series consists of a total of 39 different models providing a wide variation of possible voltage, current and power combinations.

5D Series Models
Model 5D18-12 5D36-24
OPERATING RANGES
Power Ranges 0-1800W 0-3600W
Current Ranges 0-12 A 0-24 A
Voltage Range 0 – 600 V 0 – 600 V
Minimum Voltage 6.0 V @ 12 A 6.0 V @ 24 A
OPERATING MODES LED, Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050 – 9.999 / 99.99 / 999.9 / 9999ms (20 kHz)
Slew Rate 2.4mA-150mA / μs
9.6mA-600mA / μs
4.8mA-300mA / μs
19.2mA-1200mA / μs
METERING
Voltage Range 0 – 60.0 V / 0-300.0 V / 0-600.0 V
Current Range 0-3.0A / 0-12.0A 0-6.0A / 0-24.0A
Power Range 0 – 1800.0 W 0 – 3600.0 W
AC INPUT & PHYSICAL SPECIFICATIONS
AC Input 115/230 Vac ±10%, 50/60Hz
Cooling Variable Speed Fan Cooled
Dimensions (HxWxD) 177 x 440 x 445 mm / 7.0″ x 17.3″ x 17.5″ 839 x 600 x 600 mm / 33.0″ x 23.6″ x 23.6″
Weight (Net) 23.6 kg / 52.0 lbs 81.2 kg / 179 lbs
5L Series Models
Model 5L06-12 5L12-12 5L12-24 5L18-12 5L18-24 5L18-36
OPERATING RANGES
Power Ranges 0-60W / -600W 0-120W / -1200W 0-120W / -1200W 0-180W / -1800W 0-180W / -1800W 0-180W / -1800W
Current Ranges 0-12A / 0-120 A 0-12A / 0-120 A 0-24A / 0-240 A 0-12A / 0-120 A 0-24A / 0-240 A 0-36A / 0-360 A
Voltage Range 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V
Minimum Voltage 0.6 V @ 120 A 0.6 V @ 120 A 0.7 V @ 240 A 0.4 V @ 120 A 0.7 V @ 240 A 0.7 V @ 360 A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050 – 9.999 / 99.99 / 999.9 / 9999ms (20 kHz)
Slew Rate 8mA-500mA / μs
80mA-5A / μs
16mA-1A / μs
160mA-10A / μs
8mA-500mA / μs
80mA-5A / μs
8mA-500mA / μs
80mA-5A / μs
16mA-1A / μs
160mA-10A / μs
24mA-1500mA / μs
240mA-15A / μs
METERING
Voltage Range 0 – 6.0 V / 60.0 V
Current Range 0-12A / 120A 0-12A / 120A 0-24A / 240A 0-12A / 120A 0-24A / 240A 0-36A / 360A
Power Range 0 – 600.0 W 0 – 1200.0 W 0 – 1200.0 W 0 – 1800.0 W 0 – 1800.0 W 0 – 1800.0 W
AC INPUT & PHYSICAL SPECIFICATIONS
AC Input 115/230 Vac ±10%, 50/60Hz
Cooling Variable Speed Fan Cooled
Dimensions (HxWxD) 177 x 440 x 445 mm / 7.0″ x 17.3″ x 17.5″
Weight (Net) 15.2kg / 33.5lbs 19.4kg / 42.8lbs 19.4kg / 42.8lbs 23.6kg / 52.0lbs 23.6kg / 52.0lbs 23.6kg / 52.0lbs
5P Series Models
Model 5P024-24 5P024-48 5P036-24 5P036-48 5P036-72 5P054-36 5P054-72
OPERATING RANGES
Power Ranges 0-240 W
/0-2400 W
0-240 W
/0-2400 W
0-360 W
/0-3600 W
0-360 W
/0-3600 W
0-360 W
/0-3600 W
0-540 W
/0-5400 W
0-540 W
/0-5400 W
Current Ranges 0-24A /0-240A 0-48A /0-480A 0-24A /0-240A 0-48A /0-480A 0-72A /0-720A 0-36A /0-360A 0-72A /0-720A
Voltage Range 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V
Minimum Voltage 0.6 V @ 240 A 0.7 V @ 480 A 0.6 V @ 240 A 0.7 V @ 480 A 0.7 V @ 720 A 0.6 V @ 360 A 0.7 V @ 720 A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050-9.999 /99.99 /999.9 /9999ms (20 kHz)
Slew Rate 0.016A-1A /μs
0.16A-10A /μs
0.032A-2A /μs
0.32A-20A /μs
0.016A-1A /μs
0.16A-10A /μs
0.016A-1A /μs
0.16A-10A /μs
0.048A-3A /μs
0.48A-30A /μs
0.024A-1.5A /μs
0.24A-15A /μs
0.048A-3A /μs
0.48A-30A /μs
METERING
Voltage Range 0 – 6 V /60 V
Current Range 0 – 24A /240A 0 – 48A /480A 0 – 24A /240A 0 – 48A /480A 0 – 72A /720A 0 – 36A /360A 0 – 72A /720A
Power Range 0 – 2400.0 W 0 – 2400W 0 – 2400W 0 – 3600W 0 – 3600W 0 – 5400W 0 – 5400W
SHORT CIRCUIT CURRENT 240 A 480 A 240 A 480 A 720 A 360 A 720 A
AC INPUT & PHYSICAL SPECIFICATIONS
AC Input/Cooling 115/230 Vac ±10%, 50/60Hz /Variable Speed Fan Cooled
Dimensions (HxWxD) 839 x 600 x 600 mm /33.0″ x 23.6″ x 23.6″
Weight (Net) 81.2kg /
179.0lb
72.8kg /
160.5lbs
81.2kg /
179.0lbs
81.2kg /
179.0lbs
81.2kg /
179.0lbs
104.8kg /
231lbs
104.8kg /
231lbs
Model 5P054-99 5P072-48 5P072-96 5P090-60 5P108-72 5P126-84 5P144-96
OPERATING RANGES
Power Ranges 0 – 540 W /
0 – 5400 W
0 – 720 W /
0 – 7200 W
0 – 720 W /
0 – 7200 W
0 – 900 W /
0 – 9000 W
0 – 1080 W /
0 – 10800 W
0 – 1260 W /
0 – 12600 W
0 – 1440 W /
0 – 14400 W
Current Ranges 0-100 A /
0-1000 A
0-48 A /
0-480 A
0-96 A /
0-960 A
0-60 A /
0-600 A
0-72 A /
0-720 A
0-84 A /
0-840 A
0-96 A /
0-960 A
Voltage Range 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V 0 – 60 V
Minimum Voltage 0.7 V @ 1000A 0.6 V @ 480 A 0.6 V @ 960 A 0.6 V @ 600 A 0.6 V @ 720 A 0.6 V @ 840 A 0.6 V @ 960 A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050-9.999 /99.99 /999.9 /9999ms (20 kHz)
Slew Rate 0.0664A-4.15A /μs
0.644A-41.5A /μs
0.032A-2A /μs
0.32A-20A /μs
0.064A-4A /μs
0.64A-40A /μs
0.04A-2.5A /μs
0.4A-25A /μs
0.048A-3A /μs
0.48A-30A /μs
0.056A-3.5A /μs
0.56A-35A /μs
0.064A-4A /μs
0.64A-40A /μs
METERING
Voltage Range 0 – 6 V /60V
Current Range 0-100A /1000A 0-48A /480A 0-96A /960A 0-60A /600A 0-72A /720A 0-84A /840A 0-96A /960A
Power Range 0 – 5400W 0 – 7200W 0 – 7200W 0 – 9000W 0 – 10800W 0 – 12600W 0 – 14400W
SHORT CIRCUIT CURRENT 1000 A 480 A 960 A 600 A 720 A 840 A 960 A
AC INPUT & PHYSICAL SPECIFICATIONS
AC Input/Cooling 115/230 Vac ±10%, 50/60Hz /Variable Speed Fan Cooled
Dimensions (HxWxD) 839 x 600 x 600 mm
33″x23.6″x23.6″
1061 x 600 x 600 mm
41.8″ x 23.6″ x 23.6″
1283 x 600 x 600 mm
50.5″ x 23.6″ x 23.6″
1506x600x600mm
59.3″x23.6″x23.6″
1728x600x600mm
68″x23.6″x23.6″
Weight (Net) 104.8kg /231.0 lbs 161.4kg /355.8lbs 161.4kg /355.8 lbs 185.0kg /407.9 lbs 208.6kg /459.9 lbs 232.2kg /511.9 lbs 268.8kg /592.6 lbs
5V Series Models
Model 5V006-02 5V012-04 5V018-01 5V018-06 5V024-08 5V036-12
OPERATING RANGES
Power Ranges 0-60 W /0-600 W 0-120 W /0-1200 W 0-180 W /0-1800 W 0-180 W /0-1800 W 0-240 W /0-2400 W 0-360 W /0-3600 W
Current Ranges 0-2.0 A /0-20 A 0-4.0 A /0-40 A 0-1.2 A /0-12 A 0-6.0 A /0-60 A 0-8.0 A /0-80 A 0-12.0 A /0-120 A
Voltage Range 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V
Minimum Voltage 4 V @ 20 A 4 V @ 40 A 6 V @ 12 A 4 V @ 60 A 4 V @ 80 A 4 V @ 120 A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050 – 9.999 /99.99 /999.9 /9999ms (20 kHz)
Slew Rate 1.6mA – 100mA/μs
16mA – 1000mA/μs
3.2mA – 200mA/μs
32mA – 2000mA/μs
0.96mA – 60mA/μs
9.6mA – 600mA/μs
4.8mA – 300mA/μs
48mA – 3000mA/μs
6.4mA – 400mA/μs
64mA – 4000mA/μs
9.6mA – 600mA/μs
96mA – 6000mA/μs
METERING
Voltage Range 0 – 60.0 V /600.0 V
Current Range 0-2.0A /20.0A 0-4A /40A 0-1.2A /12A 0-6A /60A 0-8A /80A 0-12A /120A
Power Range 0-60W /600W 0-120W /1200W 0-180W /1800W 0-180W /1800W 0-240W /2400W 0-360W /3600W
AC INPUT & PHYSICAL SPECIFICATIONS
AC Input 115/230 Vac ±10%, 50/60Hz
Cooling Variable Speed Fan Cooled
Dimensions (HxWxD) 177 x 440 x 445 mm
7.0″ x 17.3″ x 17.5″
839 x 600 x 600 mm
33.0″ x 23.6″ x 23.6″
Weight (Net) 15.2kg /33.5 lbs 19.4kg /42.8 lbs 23.6kg /52.0 lbs 23.6kg /52.0 lbs 72.8kg /160.5 lbs 81.2kg /179.0 lbs
Model 5V036-02 5V054-04 5V054-18 5V072-05 5V072-24 5V090-06
OPERATING RANGES
Power Ranges 0-360 W /0-3600 W 0-540 W /0-5400 W 0-540 W /0-5400 W 0-720 W /0-7200 W 0-720 W /0-7200 W 0-900 W /0-9000 W
Current Ranges 0-2.4 A /0-24 A 0-3.6 A /0-36 A 0-18 A /0-180 A 0-4.8 A /0-48 A 0-24A /0-240 A 0-6.0 A /0-60 A
Voltage Range 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V
Minimum Voltage 6 V @ 24 A 6 V @ 36 A 5 V @ 180 A 3 V @ 48 A 4 V @ 240 A 6 V @ 60 A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050 – 9.999 /99.99 /999.9 /9999mS (20 kHz)
Slew Rate 1.92mA – 120mA/μs
19.2mA – 1200mA/μs
2.88mA – 180mA/μs
28.8mA – 1800mA/μs
14.4mA – 900mA/μs
144mA – 9A/μs
0.0192A – 1.2A/μs
0.192A – 12A/μs
0.0192A – 1.2A/μs
0.192A – 12A/μs
4.8mA – 300mA/μs
48mA – 3000mA/μs
METERING
Voltage Range 0 – 60 V /500 V
Current Range 0-2.4A /24A 0-3.6A /36A 0-18A /180A 0-4.8A /48A 0-24A /240A 0-6A /60A
Power Range 0-360W /3600W 0-540W /5400W 0-540W /5400W 0-720W /7200W 0-720W /7200W 0-900W /9000W
AC INPUT & PHYSICAL SPECIFICATIONS
AC Input/Cooling 115/230 Vac ±10%, 50/60Hz /Variable Speed Fan Cooled
Dimensions (HxWxD) 839 x 600 x 600 mm
33.0″ x 23.6″ x 23.6″
1061 x 600 x 600 mm
41.8″ x 23.6″ x 23.6″
1283x600x600mm
50.5″x23.6″x23.6″
Weight (Net) 81.2kg /179.0 lbs 104.8kg /231.0lbs 104.8kg /231.0lbs 161.4kg /355.8lbs 161.4kg /355.8lbs 185.0kg /407.9lbs
Model 5V090-30 5V108-36 5V108-07 5V126-42 5V144-50
OPERATING RANGES
Power Ranges 0-900 W /0-9000 W 0-1080 W /0-10800 W 0-1080 W /0-10800 W 0-1260 W /0-12600 W 0-1440 W /0-14400 W
Current Ranges 0 – 30A /0 – 300 A 0 – 36 A /0 – 360 A 0 – 7.2 A /0 – 72 A 0 – 42 A /0 – 420 A 0 – 50 A /0 – 500 A
Voltage Range 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V 0 – 500 V
Minimum Voltage 4 V @ 300 A 4 V @ 360 A 6 V @ 72 A 4 V @ 420 A 4 V @ 500 A
OPERATING MODES Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), Constant Power (CP)
PROTECTION Over Power (OP), Over Current (OC), Over Voltage (OV), Over Temperature (OT)
DYNAMIC OPERATION
T high & T low 0.050 – 9.999 /99.99 /999.9 /9999mS (20 kHz)
Slew Rate 0.024A – 1.5A/μs
0.24A – 15A/μs
0.0288A – 1.8A/μs
0.288A – 18A/μs
5.76mA – 360mA/μs
57.6mA – 3600mA/μs
0.0336A – 2.1A/μs
0.336A – 21A/μs
0.04A – 2.5A/μs
0.4A – 25A/μs
METERING
Voltage Range 0 – 60.0 V /500 V
Current Range 0-30A /300A 0-36A /360A 0-7.2A /72A 0-42A /420A 0-50A /500A
Power Range 0-900W /9000W 0-1080W /10800W 0-1080W /10800W 0-1260W /12600W 0-1440W /14400W
SHORT CIRCUIT CURRENT 300 A 360 A 72 A 420 A 504 A
AC INPUT & PHYSICAL SPECIFICATIONS
AC Input/Cooling 115/230 Vac ±10%, 50/60Hz /Variable Speed Fan Cooled
Dimensions (HxWxD) 1283 x 600 x 600 mm
50.5″ x 23.6″ x 23.6″
1506x600x600mm
59.3″x23.6″x23.6″
1728x600x600mm
68″x23.6″x23.6″
Weight (Net) 185.0kg /407.9 lbs 208.6kg /459.9 lbs 208.6kg /459.9 lbs 232.2kg /511.9 lbs 268.8kg /592.6 lbs
600W, 1200W or 1800W per Chassis
Up to 14,400W per Cabinet
Low Voltage Range, 0 – 6 Vdc
Current Ranges up to 1000 Adc
High-Speed 5 Digit Precision Metering Capability
Parallel Operation for High Power Applications
Synchronized Operation of Multiple Loads
Operating Modes: CC, CP, CR and CV
Special High Power LED Loads (5D Series)
Built-in Short Circuit Test
Over Current Protection Test Mode
Over Power Protection Test Mode
Static and Dynamic CC Modes
Available Interface Options are USB, RS232, GPIB and LAN
CE Mark
Load Versatility

All APS 5 Series Loads are equipped with a powerful microcontroller and user friendly controls to provide capabilities that cover a wide range of load applications. Precision metering of Voltage, Current, Power and Resistance is standard.

Power Supply Testing

Elaborate testing of linear and switch mode AC/DC power supplies at high speeds is made possible by flexible ranging and wide V-I operating curves found in all 5 Series APS loads. This supports high throughput production test and burn-in of power supplies.

Power Supply Design

With built-in features like over current protection (OPC) test and over power protection (OPP) test and dynamic constant current waveform testing, new power supply designs can be thoroughly evaluated against design specifications. An analog input mode allows arbitrary current waveforms to be applied to a unit under test as well.

Battery Charge/Discharge Testing

Time sequencing of specific discharge current levels as a function of battery voltage allows characterization and performance testing of various battery chemistry. The high current resolution and accuracy of the 5 Series load supports testing of both small and large batteries.

LED Driver Testing

The 5D Series LED loads are designed for development and testing of LED power supplies, drivers and light fixtures.  These load can simulate high brightness LED characteristics for series and parallel string configurations. This significantly speeds up development and test by eliminating the need to keep multiple actual LED types on hand.
Related Products
3A Series MODULAR AC & DC LOADS

3A Series MODULAR AC & DC LOADS

Model : 3A Series
4 Series MODULAR DC LOADS

4 Series MODULAR DC LOADS

Model : 4 Series
5VP Series HIGH POWER PROGRAMMABLE DC LOADS

5VP Series HIGH POWER PROGRAMMABLE DC LOADS

Model : 5VP Series
3B Series PROGRAMMABLE AC & DC LOADS

3B Series PROGRAMMABLE AC & DC LOADS

Model : 3B Series

Products

  • EM TEST
  • WEETECH
  • PACIFIC POWER SOURCE
  • SYSTEM INTEGRATION

Navigation

  • About Us
  • Products
  • Hot Products
  • News
  • Contact Us
  • Site Map
  • Privacy Policy

Contact Us

  • TEL: 886-2-29178080
  • FAX: 886-2-29172626
  • Email: sales@excen-tech.com
  • Address:
    3F-2, No. 92, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan

© 2025 EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch All rights reserved.