Audio transformer assembly
CN 200N1 - Single-box transformer assembly for LF conducted immunity testing
The CN 200N1 is a standalone coupling network unifying two audio transformers being individually configurable for various test requirements (e.g. Ford FMC1278, German Lloyd GL VI-7-2 and SAE J1113-2). The CN 200N1 is used to apply the test signals to the lines under test via an audio transformer to perform ripple voltage tests and continuous or transient conducted immunity tests.
- One-box transformer and 0.5 ohm load assembly
- Frequency response 10 Hz to 250 kHz
- Secondary saturation 50 A per transformer
- Audio power 2 x 200 W
- Freely configurable on primary/secondary; serial, parallel, single
- Turns ratio 2:1 step down
- Built-in non-inductive load resistor 0.5 ohm, 250 W
CN 200N1 - Fully contained coupling device as per Ford FMC1278
The CN 200N1 is an easy-to-use coupling device consisting of two audio transformers and a 0.5 ohm/250 watt load resistor configurable as required by Ford FMC1278, Fig. 22-6 for AC ground voltage offset testing. The two transformers need to be connected in series on their primary side, their secondary side is paralleled and loaded by the 0.5 ohm non-inductive resistor load.
Chrysler CS-11809 (2009)
DaimlerChrysler DC-10615
DO 160 Section 16
DO 160 Section 18
Ford EMC-CS-2009.1
Ford FMC1278
GLloyd VI-7-2
ISO 11452-10
EMC-CS-2010JLR V1.1 (2011-01)
MIL STD 461 D CS 101
MIL STD 461 D CS 109
MIL STD 461 E CS 101
MIL STD 461 E CS 109
MIL STD 461 F CS 101
MIL STD 461 F CS 109
MIL STD 461 G CS 101
MIL STD 461 G CS 109
MIL-STD-704
Mitsubishi ES-X82115
SAE J1113-2
Tata TST/TS/WI/257