Calibration Set for OEM LV 124 and related Standards
VERIFICATION SET FOR PFM 200N100.X FOR VERIFY THE PULSES E10 AND E13 OF THE LV 124 STANDARDS
The CA LV 124 set includes four load resistors for the verification of the pulses E10 and E13 of the LV 124 (2013). The load resistors CA LV124-P1R and CA LV124-P100R are used for power line verification. For verification the 16 signal- and datalines the CA LV124-D1R and CA LV124-D1000R are used.
- Low inductive load resistor for direct connect into the PFM 200N100 output power plugs
- Load resistor 1.0 ohm and 100 ohm for power lines verification
- Load resistor 1.0 ohm and 1000 ohm for data lines verification
- High precision load resistors 1.0, 100 and 1000 ohms
-
Software procedure for verification with CA LV124 loads
Power Line verification
Test procedure
The load resistor must have the following characteristics to achieve the required pulse parameters:
- Low Inductive Component
- Shortest possible cables (a few cm) to the PFM output
- Probe must be as near as possible to the load resistor or, as with the CA LV 124-P, using a BNC connection directly on the load.
Signal and Datalines
Test procedure
One reference measurement each with 1 k ohm (±5%) and 1 ohm (±5%) as a DUT substitute must be performed and documented. Verification of the edge steepness must be provided with this test setup. Low-inductance parts must be used as resistors.
During the test, all even and odd I/O lines are switched alternately at the same time. With the test adapter is guaranteed that only one line is charged at each time.
BMW GS 95024-2-1
MBN LV 124-1
OEM LV 124
OEM LV 124 (2013-02)
VW 80000