Home » Products » EM TEST » Harmonics & Flicker »

Digital Power analyzer for harmonics & flicker testing

Products

  • EM TEST
    • Automotive EMC Test Solutions
    • ESD Simulators
    • EMS Compact Generators
    • Voltage Surge Generators
    • Telecom Surge Generators
    • Conducted LF/RF Immunity Testing
    • Harmonics & Flicker
  • WEETECH
    • Low Voltage Cable Test
    • High Voltage Cable Test
    • Functional Test
    • Backplane/Chassis Test
  • PACIFIC POWER SOURCE
    • PPST
      • AMX Series
      • ACX Series
      • ASX Series
      • AFX Series
      • MS Series
      • G Series
    • APS
      • AC & DC Loads
      • AC & AC Sources
      • APS Software
    • STS
      • Battery Element Testers
      • Model 1740 Test System
    • ZENONE
      • GI Series
      • GI -SI Series
      • GIS Series
      • GV Series
      • GTS Series
      • FVC Series
      • AL3000 Series
      • AL3000R Series
  • SYSTEM INTEGRATION
    • CISPR 25 Radiation & Conduction Measurement
    • ISO 10605 Electrostatic Discharge (ESD)
    • ISO 7637-2: Electrical transient conduction along supply lines only
      • Transient emission
      • Transient Immunity
        • Pulse 1
        • Pulse 2a
        • Pulse 3a/3b
        • Pulse 2b
        • Pulse 4
        • Pulse 5
    • ISO 7637-3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    • ISO 16750-2: Environmental conditions and testing
    • ISO 11452-2: Absorber-lined shielded enclosure
    • ISO 11452-4: Harness excitation methods (Including BCI method)
    • ISO 11452-5: Stripline
    • ISO 11452-8: Immunity to magnetic fields
    • ISO 11452-9: Portable Transmitters testing

Digital Power analyzer for harmonics & flicker testing

  • Digital Power analyzer for harmonics & flicker testing

Model : DPA 500N

Q'ty :

Add To Inquiry

  • Digital Power analyzer for harmonics & flicker testing DPA 500N
  • Description
  • Specifications
  • Features
  • Applications

DPA 500N - Full-compliant single phase harmonics and flicker analyzer

Harmonics and interharmonics are caused by modern electronic power conditioning modules. Such, mostly non-linear, modules to control loads and to reduce power consumption is the source of voltage at unwanted frequencies superposed on the supply voltage.

Voltage fluctuations caused by varying load currents may influence the luminance or the spectral distribution of lighting systems. The impression of the unsteadiness of visual sensation induced by this light stimulus is called flicker.

The DPA500N harmonics and flicker analyzer is used for single phase applications.

  • Real-time data acquisition
  • Internal hard disk for data storage
  • 16-Bit A/D converter
  • Wide-range current input
  • Wide-range voltage input
  • Built-in lumped flicker impedance
  • High-sophisticated analyzing capability
  • USB interface for control and data transfer

Benefits

The fully compliant harmonics and flicker analyzer

The DPA 500N is a fully compliant analyzer for harmonics and flicker as per the latest IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 requirements. It follows the design specifications as per IEC/EN 61000-4-7:2002 and Am.1:2008 (for Class A instruments) and IEC/EN 61000-4-15:2010.

Based on a real-time kernel and equipped with its own harddisk it allows to record the measuring data continuously without any gaps or overlapping. The rectangular measurement window is synchronized to each group of 10 or 12 cycles of the mains supply frequency (50Hz or 60Hz) by means of a digital PLL (Phase Lock Loop). A wide-range current input (up to 50A) avoids loss of measured data due to range switching that would occur when using different shunt resistors.

The classification of the measurement can be selected at any time, before or after the measurement has been performed. During all measurements the AC supply voltage is measured simultaneously with the current.

The built-in flicker impedance, which is automatically selected when doing flicker measurement, makes the DPA 500N a complete single-box unit for both harmonics and flicker analysis.

By means of an external current clamp (optional) the current range can be extended up to 140Arms and more.

Software
dpa.control - The control and analysing software for Harmonics and Flicker

dpa.control is the software tool needed for the operation of the harmonics and flicker analysing system. It offers all features to control the DPA 500N, to upload the recorded measuring data and for the classification and analysis. It includes analysis as per the latest standards as well as procedures following the former standard requirements. An easy Fail/Pass function allows fast analysis while detailed data is available for extended analysis and EUT evaluation purposes.

dpa.control offers a powerful documentation capability with direct export to Word.

Other Models
DPA 500 Harmonics and Flicker Analyzer Series

EM TEST offers two models of analyzers for harmonics and flicker for single phase applications (DPA 500N) and three-phase applications (DPA 503). The three-phase analyzer DPA503 can be used for single phase analysis as well.

Auxiliary Devices
ACS 500N6 - Single phase AC voltage source 6kVA

The ACS 500N6 single phase AC voltage source is used to provide a pure AC supply voltage for harmonics and flicker analysis as recommended by IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2. It offers a rated power of 6kVA and the output voltage ranges up to 300V.

The ACS 500N6 AC voltage source is controlled by dpa.control.

ACS 500N3 - Single phase AC voltage source 3kVA

The ACS 500N3 single phase AC voltage source is used to provide a pure AC supply voltage for harmonics and flicker analysis as recommended by IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2. It offers a rated power of 3kVA and the output voltage ranges up to 300V. This AC voltage source is used for low-power applications.

The ACS 500N3 AC voltage source is controlled by dpa.control.

EN 301489-1
EN 301489-17
EN 301489-24
EN 301489-7
EN 61000-3-2
EN 61000-3-3
EN 61000-4-15
EN 61000-4-7
EN 61000-6-1
EN 61000-6-2
IEC 60601-1-2
IEC 61000-3-11
IEC 61000-3-12 Ed.2:2011
IEC 61000-3-2
IEC 61000-3-3
IEC 61000-4-15 Ed.2:2010
IEC 61000-4-7
IEC 61326
JIS C 61000-3-2
Related Products
3-Phase Digital Power Analyzer for harmonics & flicker testing

3-Phase Digital Power Analyzer for harmonics & flicker testi...

Model : DPA 503N
Three-phase Multifunctional AC/DC Power Sources

Three-phase Multifunctional AC/DC Power Sources

Model : NetWave Series 3-phase
3-Phase AC Voltage Sources, 16 kVA up to 90 kVA

3-Phase AC Voltage Sources, 16 kVA up to 90 kVA

Model : ACS 503N-series
Programmable Multifunctional AC/DC Power Sources

Programmable Multifunctional AC/DC Power Sources

Model : NetWave Series 1-phase
Single Phase AC Voltage Source 3 kVA

Single Phase AC Voltage Source 3 kVA

Model : ACS 500N3
Three-Phase flicker impedances up to 75A

Three-Phase flicker impedances up to 75A

Model : AIF 503N-series

Products

  • EM TEST
  • WEETECH
  • PACIFIC POWER SOURCE
  • SYSTEM INTEGRATION

Navigation

  • About Us
  • Products
  • Hot Products
  • News
  • Contact Us
  • Site Map
  • Privacy Policy

Contact Us

  • TEL: 886-2-29178080
  • FAX: 886-2-29172626
  • Email: sales@excen-tech.com
  • Address:
    3F-2, No. 92, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan

© 2025 EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch All rights reserved.