LF signal & amplifier DC (0Hz) to 250kHz (500kHz), 800W

Products

  • EM TEST
    • Automotive EMC Test Solutions
    • ESD Simulators
    • EMS Compact Generators
    • Voltage Surge Generators
    • Telecom Surge Generators
    • Conducted LF/RF Immunity Testing
    • Harmonics & Flicker
  • WEETECH
    • Low Voltage Cable Test
    • High Voltage Cable Test
    • Functional Test
    • Backplane/Chassis Test
  • PACIFIC POWER SOURCE
    • PPST
      • AMX Series
      • ACX Series
      • ASX Series
      • AFX Series
      • MS Series
      • G Series
    • APS
      • AC & DC Loads
      • AC & AC Sources
      • APS Software
    • STS
      • Battery Element Testers
      • Model 1740 Test System
    • ZENONE
      • GI Series
      • GI -SI Series
      • GIS Series
      • GV Series
      • GTS Series
      • FVC Series
      • AL3000 Series
      • AL3000R Series
  • SYSTEM INTEGRATION
    • CISPR 25 Radiation & Conduction Measurement
    • ISO 10605 Electrostatic Discharge (ESD)
    • ISO 7637-2: Electrical transient conduction along supply lines only
      • Transient emission
      • Transient Immunity
        • Pulse 1
        • Pulse 2a
        • Pulse 3a/3b
        • Pulse 2b
        • Pulse 4
        • Pulse 5
    • ISO 7637-3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    • ISO 16750-2: Environmental conditions and testing
    • ISO 11452-2: Absorber-lined shielded enclosure
    • ISO 11452-4: Harness excitation methods (Including BCI method)
    • ISO 11452-5: Stripline
    • ISO 11452-8: Immunity to magnetic fields
    • ISO 11452-9: Portable Transmitters testing

LF signal & amplifier DC (0Hz) to 250kHz (500kHz), 800W

  • AMP 200N1.1-LF signal & amplifier DC
  • Testing as per Ford EMC-CS-2009.1, CI250
  • Set-up EMC-CS-2009 testing
  • Ford FMC1278, Figure 22-6

Model : AMP 200N1.1

Q'ty :

Add To Inquiry

  • AMP 200N1.1-en
  • AMP 200N1.1-zh-cn
  • Description
  • Specifications
  • Features
  • Applications

AMP 200N1.1 - Low-frequency signal / amplifier for supply simulation and magnetic field testing

The AMP 200N1.1 has been designed as a low-frequency signal source to generate sinusoidal signals used to simulate ripple noise and ground shift noise as required by a variety of standards in the avionics, military and automotive industry. 

The AMP 200N1.1 is controlled by either the NetWave (for testing avionics, military and nautic standard requirements, e.g German Lloyd VI-7-2) the AutoWave for automotive testing such as e.g. Ford FMC1278. Additionally, the AMP 200N1.1 can be used to generate magnetic fields by means of a radiation loop or small Helmholtz coils as per various standards.


  • Automatic Closed Loop test procedures
  • Built-in DDS sinus signal generator up to 250 kHz
  • High frequency option up to 500 kHz
  • Output voltage max. 140V p-p, 50V rms
  • Output current max. 16A rms
  • Supports magnetic field tests up to 1100 A/m
  • Short-circuit protected
  • Integrated voltage measurement 10Hz - 250kHz (optional)
  • Integrated frequency-selective current measurement 10Hz - 250kHz (optional)
  • Integrated field strength measurement (optional)
  • Safety interlock
  • Built-in LF amplifier, 800W
  • Supports German Lloyd VI-7-2


 Benefits


AMP 200N1.1 - Signal generator/amplifier solution for ripple noise and magnetic field testing



The AMP 200N1.1 unifies a low-frequency signal generator and a powerful amplifier module giving a maximum amplitude of 140V peak-to-peak as required e.g. by German Lloyd VI-7-2 or by Ford FMC1278. It generates both sinusoidal and transient signals. 



Equipped with a DDS it generates any sinusoidal signal with a frequency up to 250kHz (500 kHz with HF option). The AMP 200N1.1 is controlled by the EM TEST AutoWave or the NetWave in order to generate any sinusoidal or non-sinusoidal/transient signals and is therefore fully supported by the autowave.control software with its exhaustive library of pre-programmed standards and its outstanding reporting and documentation capabilities.



The AMP 200N1.1 can also be used for magnetic field testing using a Radiation Loop and Loop Sensor. Extended by the optional measuring module the AMP 200N1.1 offers means for frequency-selective current measurement, voltage measurement and measurement of the magnetic field strength.


 Ford FMC1278, CI 250 testing 

Immunity to Ground Offset


The AMP 200N1.1 can be used for testing the immunity to ground offset noise as per Ford FMC1278, CI 250. 

Both the continuous as well as the transient signal are generated by means of the AMP 200N1.1, controlled by the AutoWave. The CN 200N1 is used to couple the test signals on to the line under test.





 Ford FMC1278, RI 140, RI 150, CI 210


Magnetic Field Testing (RI 140), Continuous Distubance testing (RI 150) and Immunity from Power Line Disturbances (CI 210)

The AMP 200N1.1 is designed for immuntiy testing and magnetic field testing as per Ford FMC1278. 
For RI 140 magnetic field testing a Radiation loop and current clamp to measure the induced current is required. 
For RI 150 testing a test fixture is needed to represent the injection loop. 
For CI 210 Immunity testing from continuous power line disturbances the AMP 200N1.1 generates the control signal to drive a programmable DC source, e.g. a VDS 200N or VDS 200Q.




 Auxiliary Devices


CN 200N1 - Single-box transformer assembly for LF conducted immunity testing

The CN 200N1 is an easy-to-use coupling device consisting of two audio transformers and a 0.5ohm/250watt load resistor configurable as required by Ford FMC1278, Fig. 22-6 for AC ground voltage offset testing. The two transformers need to be connected in series on their primary side, their secondary side is paralleled and loaded by the 0.5ohm non-inductive resistor load.





Chrysler CS-11809 (2009)
Chrysler CS-11979
Chrysler DC-11224 Rev.A
DaimlerChrysler DC-10614
DaimlerChrysler DC-10615
DaimlerChrysler DC-11224
Fiat 9.90110
Ford EMC-CS-2009.1
Ford ES-XW7T-1A278-AC
Ford FMC1278
GLloyd VI-7-2
GMW 3097 (2006)
GMW 3172
ISO 11452-10
ISO 11452-8
EMC-CS-2010JLR V1.1 (2011-01)
MAN 3285
MBN 10284-2
Nissan 28400 NDS 02
PSA B21 7110 Rev.C, Ad. 2010-05
Renault 36.00.808/--G
Renault 36.00.808/--H
Renault 36.00.808/--J
Renault 36.00.808/--K
Renault 36.00.808/--L
SAE J1113-2
Tata TST/TS/WI/257
Volvo STD 515-0003
VW TL 825 66


Related Products
Generates and records automotive waveforms

Generates and records automotive waveforms

Model : AutoWave

Products

  • EM TEST
  • WEETECH
  • PACIFIC POWER SOURCE
  • SYSTEM INTEGRATION

Navigation

  • About Us
  • Products
  • Hot Products
  • News
  • Contact Us
  • Site Map
  • Privacy Policy

Contact Us

  • TEL: 886-2-29178080
  • FAX: 886-2-29172626
  • Email: sales@excen-tech.com
  • Address:
    3F-2, No. 92, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan

© 2025 EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch All rights reserved.