Low frequency signal source DC (0Hz) to 250kHz
- Built-in DDS to generate sinusoidal signals up to 250kHz
- Built-in LF amplifier, 250W
- Output voltage max. 140V p-p, 50V rms
- Output current max. 5A rms
- Programmable DC voltage offset
- Controlled by AutoWave and autowave.control via Framebus
- Integrated voltage measurement 10Hz - 250kHz (optional)
- Integrated field strength measurement (optional)
- Integrated frequency-selective current measurement 10Hz - 250kHz (optional)
- Safety interlock
Benefits
AMP 200N - Signal generator/amplifier solution for ripple noise and magnetic field testing
The AMP 200N unifies a low-frequency signal generator and a powerful amplifier module giving a maximum amplitude of 150V peak-to-peak as required e.g. by Ford EMC-CS-2009.1. It generates both sinusoidal and transient signals. Equipped with a DDS it generates any sinusoidal signal with a frequency up to 250kHz. The AMP 200N is controlled by the EM TEST AutoWave in order to generate any sinusoidal or non-sinusoidal/transient signals and is therefore fully supported by the autowave.control software with its exhaustive library of pre-programmed standards and its outstanding reporting and documentation capabilities.
The AMP 200N can also be used for magnetic field testing using a Radiation Loop and Loop Sensor. Extended by the optional measuring module the AMP 200N offers means for frequency-selective current measurement, voltage measurement and measurement of the magnetic field strength.
Ford EMC-CS-2009.1, CI 250 testing
Immunity to Ground Offset
The AMP 200N can be used for testing the immunity to ground offset noise as per Ford EMC-CS-2009.1, CI 250. Both the continuous as well as the transient signal are generated by means of the AMP 200N, controlled by the AutoWave. The CN 200N is used to couple the test signals on to the line under test.
Magnetic Field Testing (RI 140), Continuous Distubance testing (RI 150) and Immunity from Power Line Disturbances (CI 210)

For RI 140 magnetic field testing a Radiation loop and current clamp to measure the induced current is required.
For RI 150 testing a test fixture is needed to represent the injection loop. For CI 210 Immunity testing from continuous power line disturbances the AMP 200N generates the control signal to drive a programmable DC source, e.g. a VDS 200N.
CN 200N1 - Single-box transformer assembly for LF conducted immunity testing