EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch
  • innerBanner2
  • innerBanner1
  • innerBanner3
  • Inquiry(0)
  • 繁體中文
  • English
  • 简体中文
  • Home
  • About Us
    • PROFILE
    • MAIN BUSINESS
  • Products
    • EM TEST
    • WEETECH
    • PACIFIC POWER SOURCE
    • SYSTEM INTEGRATION
  • Hot Products
  • News
    • EXCENTECH NEWS
    • PRODUCT NEWS
  • Contact Us
    • CONTACT FORM
    • LOCATION
Home » Products » PACIFIC POWER SOURCE » PPST » MS Series »

MS Series – AC Power Converter

PACIFIC POWER SOURCE

  • EM TEST
    • Automotive EMC Test Solutions
    • ESD Simulators
    • EMS Compact Generators
    • Voltage Surge Generators
    • Telecom Surge Generators
    • Conducted LF/RF Immunity Testing
    • Harmonics & Flicker
  • WEETECH
    • Low Voltage Cable Test
    • High Voltage Cable Test
    • Functional Test
    • Backplane/Chassis Test
  • PACIFIC POWER SOURCE
    • PPST
      • AMX Series
      • ACX Series
      • ASX Series
      • AFX Series
      • MS Series
      • G Series
    • APS
      • AC & DC Loads
      • AC & AC Sources
      • APS Software
    • STS
      • Battery Element Testers
      • Model 1740 Test System
    • ZENONE
      • GI Series
      • GI -SI Series
      • GIS Series
      • GV Series
      • GTS Series
      • FVC Series
      • AL3000 Series
      • AL3000R Series
  • SYSTEM INTEGRATION
    • CISPR 25 Radiation & Conduction Measurement
    • ISO 10605 Electrostatic Discharge (ESD)
    • ISO 7637-2: Electrical transient conduction along supply lines only
      • Transient emission
      • Transient Immunity
        • Pulse 1
        • Pulse 2a
        • Pulse 3a/3b
        • Pulse 2b
        • Pulse 4
        • Pulse 5
    • ISO 7637-3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    • ISO 16750-2: Environmental conditions and testing
    • ISO 11452-2: Absorber-lined shielded enclosure
    • ISO 11452-4: Harness excitation methods (Including BCI method)
    • ISO 11452-5: Stripline
    • ISO 11452-8: Immunity to magnetic fields
    • ISO 11452-9: Portable Transmitters testing

MS Series – AC Power Converter

  • MS Series – AC Power Converter

Model : MS Series

Q'ty :

Add To Inquiry

  • MS Series – AC Power Converter
  • Description
  • Specifications
  • Features
  • Applications

Pacific’s unique master/slave configuration allows up to ten 62.5 kVA mainframes to be paralleled in the field. Any mainframe may be designated as the master. A failed unit is automatically disconnected from the power grid providing unmatched mission reliability.

Pacific’s MS-Series Power Source Systems Feature

Maximum system reliability
Rugged, powerful output
Lower installation cost
All frequency operation
Lower maintenance cost
Facility/test power flexibility
Unmatched performance/price ratio
Simple display and diagnostics
UMS Option – MS Series Battery Support Systems

The MS Series can be equipped with an optional Uninterruptible Power Battery Backup System to provide backup power in case of utility power outages. The battery support system for a single cabinet UMS installation (62.5kVA, 50kW) consists of 30 sealed, maintenance free, immobilized electrolyte, batteries installed in an open battery rack. The UMS system DC voltage regulator provides for automatic charging of the battery system to maintain the proper float voltage. A battery disconnect center is located on the end of the battery rack.

Battery support time at full load (50kW) is approximately 15 minutes. The waveform quality at the end of the battery support time meets the requirements of MIL-STD 1399, section 300A, Types I, II and III power forms.

Electrical Specifications - Output
Power:
62.5kVA/50kW for each 3060-MS.

Voltage:
0-120/208, 3 phase. May be loaded either WYE or Delta. Other voltages are available as an option.
Current:
175 Arms per phase continuous. 350Apk per phase for non-linear loads.

Load Transient Response and Recovery Time:
150 microseconds for 50% load step and 300 microseconds for 100% load step.
Load Power Factor:
Any. Unit delivers full rated kVA into any power factor.

Load Balance Restrictions:
None. Each phase is independently regulated.
Isolation:
Input is fully isolated from output and frame ground.

Protection:
Integral electronic current limiting with auto recovery. Output CB optional.
Electrical Specifications - Input
Voltage:
Universal input transformer with provisions for 208, 240, 380 and 480VAC, 3 phase + 10%.
Frequency:
47-63 Hz.
Physical Specifications
Size:
36″W x 30″D x 72″H (see diagram).

Weight:
1600 lbs., Approximately 1700 lbs. shipping weight.

Efficiency:
85 to 90%.
Solid State Technology with Unmatched Price/Performance Ratio

Pacific MS-Series is a family of High Performance Line Conditioners/Frequency Converters that provides highly flexible, yet reliable, AC power ranging from 62.5 to 625 kVA. Using field-proven double conversion methods, the MS-Series offers unmatched power quality without sacrificing size or efficiency.

Input AC power is rectified to DC by a special input power supply section. This minimizes input current distortion and prevents the load power factor from reflecting back onto the utility line. The DC is then converted back to AC by a high frequency, solid state, pulse-width modulated switchmode inverter under the control of a highly stable digital oscillator. The result is exceptional system performance with maximum reliability.
Rugged, Powerful Output

350 Amps of Pulse Current is delivered by each 3060-MS for driving non-linear loads.This eliminates the need to oversize power equirements as is common to rotary or low quality PWM power systems.
Load Power Factor is not an issue. The 3060-MS will drive virtually any load without damage or risk.
Excellent Regulation and response time eliminates load cross talk. Voltage sags common to other conversion methods are eliminated with 150 microsecond response time to a 50% load step. The output recovers to ± 3% of nominal within less than 1/10th of a cycle at 400 Hz.
Maximum Reliability

Each 3060-MS is capable of operating as either the master or slave in a multi-cabinet parallel system. Calculated single cabinet MTBF is greater than five years.
Mission Reliability is assured. The parallel system architecture is such that a failed slave unit automatically removes itself from the power grid. Should the master unit fail, the operator can select any other paralleled unit as the new master from the front panel and restore system operation.
For critical applications under conditions where utility power is unreliable, the UMS version of the MS Series provides uninterruptable battery backed operation for even greater system reliability and guaranteed up-time.
Low Cost Ownership

Lower Maintenance Costs are achieved through built-in diagnostics that minimize MTTR. Quick and easy repair is facilitated with a small complement of local spares.
Input Power Factor is a constant 0.95 lagging, regardless of load. The MS Series actually corrects PF reflected back to the utility, eliminating PF penalties.
Low Installation Cost. The MS Series fits through standard doorways. Audible noise is limited to cooling fans. There is no 400 Hz whine that requires noise isolation. Solid state design with a forklift base eliminates the need for concrete pads and vibration isolators common to rotary installations.
Facility/Test Power Flexibility

Power Levels Grow with demand. Units may be added or removed from the power grid as required.
Variable Frequency range of 47-500 Hz, as well as switch selectable fixed frequency operation of 50, 60 or 400 Hz is standard on every model (800Hz optional contact factory for more information).
External Input is provided as a standard feature. This allows operation as a variable frequency test power amplifier.
UPC-32 Programmable Controller Option is available to provide steady state and transient control of output power from the RS-232 or GPIB bus. Compatibility with UPC Studio graphical user interface.
Simple/Informative Display

Measures volts, amps, watts and kVA for each input and output phase.
Efficiency is continuously monitored allowing system performance verification.
Internal Diagnostics assist in quickly locating failed components resulting in extremely low MTTR.
Power Generation circuits are separate from display and diagnostics. A failure in the display logic will not affect output power quality. Output power cannot be interrupted by system interrogation.
Audible and Visual Alarms alert the operator to any conditions requiring attention.
Additional Features

Run time meter
Auto restart
RS-232 serial port for remote monitoring and diagnostics
Programmable voltage & frequency alarm set points
Local automatic gain control. Remote sense optional.
ETL Listing (optional on standard MS-Series cabinet only)
CE Mark (optional on standard MS-Series cabinet)
MS Series
The rugged reliability of the MS Series and the ease with which two or more MS cabinets can be paralleled to create high power solid state conversion AC power systems has resulted in its wide spread use for production test, certification test and R&D applications in Commercial as well as Avionics Industries.
Transformer Test

Testing of utility transformers requires the ability to support high magnetization currents and EMF kickback from the transformer under test. The MS series can be sized from 62.5KVA to 625KVA or even high as needed to support high power transformers. With is available range of high voltage output range options, voltages as high as 600V L-L can be supported.
Avionics Bus Simulation and Compliance Test

With the addition the SCU-UPC arbitrary waveform controller and it’s transient generation capability, complex avionics bus simulation on 400Hz systems can be programmed and executed. Using the available UPC Test Manager Windows software, pre-programmed test sequences for Airbus, RTCA DO160 Commercial aviation and MIL-STD 704 Military aviation test standards are available which eliminate the need to develop your own test programs.
For applications requiring wild frequency operation (360-800Hz), the MSA version is available. Contact Pacific Power Source Sales for more information on the MSA version.
Production and Compliance Test of High Power Products

Testing products for immunity to voltage dips and variations and/or frequency fluctuation is made easy on the MS by adding the SCU-UPC programmable controller. Pre-programmed test sequences for IEC 61000-4 AC immunity tests such as IEC 61000-4-11 are available using the UPC Test Manager windows software.
Grid-Tied Inverter Test (Solar and Wind)

For large scale grid-tied inverter development and test applications, the 3060-MS can simulate the grid to induce common AC utility anomalies these inverters must be able to handle. Since grid-tied inverters push power back onto the MS in this application, a regenerative mode configuration can be used.
Facility Power

The MS Series is an excellent source of stable AC voltage for facility wide power applications over the frequency range of 47 to 500 Hz. The standard controller has pre-sets for 50, 60 or 400Hz to lock in the desired nominal frequency. Output voltages up to 600 VAC are provided.
UMS Option
UMS Systems: On-Line, No-Risk Battery Test

This feature of the UMS system provides the ability to perform a battery test on command from the front panel or RS-232 serial port. Test results are displayed on the front panel and are available over the serial port as a part of the system diagnostics. A battery failure during the test will not cause the system to drop the load or distort the output waveform.
Related Products

Products

  • EM TEST
  • WEETECH
  • PACIFIC POWER SOURCE
  • SYSTEM INTEGRATION

Navigation

  • About Us
  • Products
  • Hot Products
  • News
  • Contact Us
  • Site Map
  • Privacy Policy

Contact Us

  • TEL: 886-2-29178080
  • FAX: 886-2-29172626
  • Email: sales@excen-tech.com
  • Address:
    3F-2, No. 92, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan

© 2025 EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch All rights reserved.