EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch
  • innerBanner2
  • innerBanner1
  • innerBanner3
  • Inquiry(0)
  • 繁體中文
  • English
  • 简体中文
  • Home
  • About Us
    • PROFILE
    • MAIN BUSINESS
  • Products
    • EM TEST
    • WEETECH
    • PACIFIC POWER SOURCE
    • SYSTEM INTEGRATION
  • Hot Products
  • News
    • EXCENTECH NEWS
    • PRODUCT NEWS
  • Contact Us
    • CONTACT FORM
    • LOCATION
Home » Products » EM TEST » EMS Compact Generators »

Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

Products

  • EM TEST
    • Automotive EMC Test Solutions
    • ESD Simulators
    • EMS Compact Generators
    • Voltage Surge Generators
    • Telecom Surge Generators
    • Conducted LF/RF Immunity Testing
    • Harmonics & Flicker
  • WEETECH
    • Low Voltage Cable Test
    • High Voltage Cable Test
    • Functional Test
    • Backplane/Chassis Test
  • PACIFIC POWER SOURCE
    • PPST
      • AMX Series
      • ACX Series
      • ASX Series
      • AFX Series
      • MS Series
      • G Series
    • APS
      • AC & DC Loads
      • AC & AC Sources
      • APS Software
    • STS
      • Battery Element Testers
      • Model 1740 Test System
    • ZENONE
      • GI Series
      • GI -SI Series
      • GIS Series
      • GV Series
      • GTS Series
      • FVC Series
      • AL3000 Series
      • AL3000R Series
  • SYSTEM INTEGRATION
    • CISPR 25 Radiation & Conduction Measurement
    • ISO 10605 Electrostatic Discharge (ESD)
    • ISO 7637-2: Electrical transient conduction along supply lines only
      • Transient emission
      • Transient Immunity
        • Pulse 1
        • Pulse 2a
        • Pulse 3a/3b
        • Pulse 2b
        • Pulse 4
        • Pulse 5
    • ISO 7637-3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    • ISO 16750-2: Environmental conditions and testing
    • ISO 11452-2: Absorber-lined shielded enclosure
    • ISO 11452-4: Harness excitation methods (Including BCI method)
    • ISO 11452-5: Stripline
    • ISO 11452-8: Immunity to magnetic fields
    • ISO 11452-9: Portable Transmitters testing

Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

  • CNV 504 / 508 T-Series-Coupling/decoupling network for unshielded symmetrical interconnection lines
  • CNV 504 / 508N
  • CNV 504 / 508 T-Series

Model : CNV 504 / 508 T-Series

Q'ty :

Add To Inquiry

  • CNV 504 / 508 T-Series
  • Description
  • Specifications
  • Features
  • Applications

CNV 504 / 508 T-series - Coupling decoupling networks for unshielded communication lines

Surge pulses and Telecom Surge pulses are applied to unshielded symmetrical interconnection lines (communication lines) by means of standalone coupling/decoupling networks. CNV 504T5 is designed for 4 lines (2 pairs), CNV 508T5 for 8 lines (4pairs) and can also be used for either 4 or 2 lines. 

According to IEC 61000-4-5 Ed.3, (Fig. 10) the pulses are coupled via gas arrestors and a matching resistor per line.


  • As per IEC 61000-4-5 Ed.3, Fig 10/A4, ITU K.44
  • For test pulse 1.2/50 - 8/20µs and 10/700µs
  • Coupling via gas arrestor or other coupling
  • Built-in matching resistors
  • 20mH decoupling, current compensated pairs
  • Test voltage up to 5kV
  • Line voltage 50V
  • Line current 1A

Surge 1.2 /50us

CNV 504 / 508 T-series - Surge coupling/decoupling networks for communication lines


The EM TEST CNV 504 / 508 T-series coupling/ decoupling networks are designed to couple Surge pulses (1.2/50us - 8/20us) and Telecom Surge pulses (10/700us) onto unshielded symmetrically operated communication lines. 

The CNV-models includes the coupling via gas arrestor plus the internal matching resistor Rc as per figure 10 of IEC 61000-4-5 Ed.3 with values as per the formula given by the standard. All lines are subjected to the test pulse simultaneously with respect to ground.

The CNV also include the required decoupling part consisting of decoupling inductors of 20mH for each line, pairwise current compensated. To further protect the auxiliary equipment being needed for testing the DUT an additional protection circuit is integrated at the communication line input.

Surge 10/700 us
CNV 504 / 508 T-series - Telecom Surge coupling/decoupling networks for communication lines

The CNV 504 / 508 T-series is also designed as per figure A4 of IEC 61000-4-5 Ed.3 without primary protector. If required, an additional primary protector must be integrated according the user specifications.

With short circuit bridges and individual designed coupling devices the user can easy modify the coupling mode and number of tested lines to the requirements.

EM TEST offers CNV 504 / 508 T-series coupling/decoupling networks for test voltages up to 5kV.

EN 61000-4-5
IEC 61000-4-5
ITU-T K.44

Related Products
Calibration Target and verification adapter for ESD

Calibration Target and verification adapter for ESD

Model : CTR2/CTR2-AD
Coupling/decoupling networks for 4 signal/data lines

Coupling/decoupling networks for 4 signal/data lines

Model : CNV 504N5 series
Combined 3-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

Combined 3-phase coupling/decoupling networks for Burst and ...

Model : CNI 503x-series
Combined 1-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

Combined 1-phase coupling/decoupling networks for Burst and ...

Model : CNI 501x-series
Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

Coupling/decoupling network for unshielded symmetrical inter...

Model : CNV 504N/508N
Load resistors for EFT/burst verification

Load resistors for EFT/burst verification

Model : CA EFT KIT

Products

  • EM TEST
  • WEETECH
  • PACIFIC POWER SOURCE
  • SYSTEM INTEGRATION

Navigation

  • About Us
  • Products
  • Hot Products
  • News
  • Contact Us
  • Site Map
  • Privacy Policy

Contact Us

  • TEL: 886-2-29178080
  • FAX: 886-2-29172626
  • Email: sales@excen-tech.com
  • Address:
    3F-2, No. 92, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan

© 2025 EXCENTECH PTE. LTD. (SINGAPORE) Taiwan Branch All rights reserved.